3061809_1210
Commissioning
Switch ON the system ON / OFF switch at the control unit.
ON / OFF switch
The heating system starts to operate with the factory settings as
soon as the ON / OFF switch at the control unit is switched ON.
Note:
The factory settings of the control unit represent empirical values.
Subject to system or equipment level, control parameters other
than those chosen at the factory can be selected. Make changes
via the Wolf control accessories or via a PC / laptop with Wolf
control software. All factory settings are stored in a non-volatile
memory.
During commissioning, the control unit automatically recognises
any connected cylinder and / or outside temperature sensor.
The outside temperature sensor is logged off by disconnection and
by switching the supply voltage OFF and ON again.
The system will not be protected against frost if no outside
temperature sensor is connected; only the boiler is frost
protected.
You can log off the cylinder sensor by disconnecting and
resetting.
The boiler sensor cannot be logged off.