3061809_1210
10
Control unit / Function / Operation
In summer mode, the circulation pump operates for approx. 10
seconds after a maximum idle period of 24 hours. Then, the
cylinder primary pump and the DHW circulation pump (if installed)
will run for 20 seconds. This prevents the pump from seizing up.
The burner will be switched OFF for approx. two minutes if it is
operating when the anti-seizing pump protection is enabled.
Anti-seizing pump
protection
Thermometer
to display the current heating water temperature.
Fine-wire fuse
M 6.3 A to protect the control PCB.
eBUS connection
for data transfer between the control unit and the PC / laptop
with the software set for boiler control units (accessory).
High limit safety cut-out STB
factory-set to 110 °C; adjustable to 100 °C, if required.