Wolf Link home Installation And Operating Instructions Manual Download Page 3

Documentation information

Documentation information

1.1 

Other applicable documents

Installation and operating instructions for the product and all accessory 

modules and further accessories.

1.2 

Safekeeping of these documents

The system user or operator should ensure the safekeeping of all instruction 

manuals.

Hand over these installation and operating instructions, along with all other 

applicable manuals, to the system user or operator.

1.3 

Applicability of these instructions

These installation and operating instructions apply to the WOLF Link home 

and WOLF Link pro interface modules both referred to as Link hereinafter.

1.4 

Symbols and warnings used

Symbol for additional information

 

X

 

Symbol for a necessary action

Warnings in the text warn you of possible risks before the start of an 

instruction. The warnings provide you with information on the possible 

severity of the risk using a pictogram and a keyword

Pictogram

Keyword

Explanation

Danger!

Risk to life or risk of serious injury

Danger!

Risk to life or risk of serious injury through 

electrocution

Warning!

Risk of minor injury

Caution!

Possible material damage

1.5 

Layout of warnings

You will recognise warnings in these instructions by pictograms and a 

line above and below the warning section. These warnings are laid out as 

follows:

Keyword

Type and source of risk.

Explanation of the risk.

 

X

Action to prevent the risk.

3

3066086_201803

Summary of Contents for Link home

Page 1: ...H 1380 D 84048 MAINBURG TEL 49 0 87 51 74 0 FAX 49 0 87 51 74 16 00 www WOLF eu Doc no 3066086_201803 Subject to modifications GB Installation and operating instructions WOLF Link home WOLF Link pro interface module WRS ...

Page 2: ... delivery 6 3 5 Overview WOLF Link home WOLF Link pro interface module 6 3 6 Function of the pushbutton 7 3 7 Meaning of the LEDs 7 3 8 Specification 7 4 Installation Electrical connection 8 4 1 Installation site requirements 8 4 2 WOLF Link home installation 8 4 3 WOLF Link pro installation 10 4 4 Decommissioning and disposal 11 4 4 1 Decommissioning 11 4 4 2 Disposal and recycling 11 5 Commissio...

Page 3: ...ed to as Link hereinafter 1 4 Symbols and warnings used Symbol for additional information X X Symbol for a necessary action Warnings in the text warn you of possible risks before the start of an instruction The warnings provide you with information on the possible severity of the risk using a pictogram and a keyword Pictogram Keyword Explanation Danger Risk to life or risk of serious injury Danger...

Page 4: ... have received instructions on how to use the appliance from this person 2 3 General safety instructions The Link interface module must be installed and commissioned by a qualified contractor Only qualified contractors may carry out the electrical installation X X Before working on the electrical installation disconnect the power supply from the appliance and all connected components X X Be aware ...

Page 5: ... condensing boiler TOB wall mounted oil condensing boiler Gas condensing boilers MGK 2 BWL 1S split air source heat pump COB oil condensing boiler MGK gas condensing boiler CGB CGW CGS FGB gas condensing boilers CGG 2 CGU 2 conventional gas boilers R2 R3 R21 boiler control units BWW 1 BWL 1 BWS 1 mono block heat pumps MM MM 2 mixer module KM KM 2 cascade module in conjunction with a WOLF Link home...

Page 6: ...s Connecting cable Network cable 3 x adhesive cable fasteners Additional label for attachment to housing 3 4 Wolf LINK pro standard delivery Check the standard delivery using the following list WOLF Link pro interface module Installation and operating instructions Network cable USB power supply unit and cable for power supply eBus connection cable 3 x strain relief Additional label for attachment ...

Page 7: ...On eBus and Modbus connection established and system detection completed Flashing System detection active WLAN Red Off WLAN disabled On WLAN connection established Flashing Connecting On for a long time briefly off Access point active Flashing quickly WPS active 3 8 Specification Designation Power supply WOLF Link home 24 VDC via PCB WOLF Link pro 5VDC via Micro USB and included power supply or 24...

Page 8: ...OFF the power supply to the appliances X X Secure the power supply against reconnection 4 1 Installation site requirements Only install the Link home interface module in the specific installation locations intended The WOLF Link pro may only be operated inside buildings and outside wet rooms 4 2 WOLF Link home installation CGB 2 CGW 2 CGS 2 and BWL 1S MGK 2 TOB X X Switch OFF the appliance and ass...

Page 9: ...X Clip the WOLF Link home in at the designated location X X Clip the WOLF Link home in at the designated location X X Clip the WOLF Link home in at the designated location HCM 2 X X In the case of network connection by network cable LAN plug this into the RJ45 socket on the WOLF Link home X X Switch on the appliance and associated components X X You can now use the WOLF Link home see instructions ...

Page 10: ...ea free of metallic objects e g cables and pipes X X Switch OFF the appliance and associated components X X Disconnect the power supply MCB or heating emergency stop switch X X Open the Wolf Link pro by undoing the screw and lifting up the cover on this side X X Carefully break out the required cable entries with a suitable tool e g needle nosed pliers 10 cm 10 cm LAN optional eBus WRS optional US...

Page 11: ...d screw it in place Use a shielded cable CAT5 minimum to connect the Modbus 4 4 Decommissioning and disposal 4 4 1 Decommissioning X X When decommissioning the interface module follow the installation sequence in reverse order X X Dispose of the interface module correctly 4 4 2 Disposal and recycling Appliance At the end of its service life do not dispose of the interface module in the household w...

Page 12: ...n on the WOLF Link home or WOLF Link pro for 3 5 seconds within 30 seconds Release when the yellow and green LEDs start flashing The red LED on the interface module will start flashing rapidly if it stays on the connection has been established 6 After approx 1 minute the yellow LED will remain on and a connection can be established via the home network 5 1 3 Please refer to www wolf smartset com f...