4)
Attach transition to existing duct-
work with sheet metal screws. Use
duct tape or silicone to make all
joints secure and air tight.
5)
If installing a remote blower, drill
7/8" hole through the wood framing
for conduit wires. See
Connect
Remote Blower
on page 12 for over-
all dimensions and electrical require-
ments. See installation instructions
provided with blower for mounting
and installation information.
IMPORTANT NOTE:
Do not run
remote blower connects through
ductwork.
6)
If installing internal blower
LBLOWER-120INT (805087) see
installation guidelines on page 11
and installation instructions provided
with blower.
8
Rough-in Plate Installation
ROUGH-IN
PLATE
HOOD
ASSEMBLY
SHIPPING
SCREWS
TRANSITION
P
R O
S
E R I E S
V
E N T I L A T I O N
H
O O D
L
I N E R S
I N S T A L L A T I O N
Step 3: Hood Liner Preparation
If installing LBLOWER-120INT
(805087), see installation for inter-
nal blower on page 11.
IMPORTANT NOTE:
Wolf recom-
mends installing the internal blower
to the rough-in plate assembly prior
to installing liner to the wall framing.
1)
The liner assembly is shipped with
the rough-in plate and the transition
attached. The transition is shipped
upside down in the top of the liner
assembly and must be removed and
reinstalled.
2)
Detach the rough-in plate / transi-
tion from the liner assembly by
removing the four (4) screws on the
top and the four (4) screws on the
back of the rough-in plate / transition
assembly.
3)
Detach the transition from the
rough-in plate by removing the four
(4) screws.
DO NOT DISCARD
SCREWS
. Shipping screws are needed
for reinstallation of transition to the
rough-in plate.