I N S T A L L A T I O N
Step 6: Install Wiring
WARNING
Before servicing or cleaning
unit, switch power off at
service panel and lock the
service disconnecting means
to prevent power from being
switched on accidentally.
When the service disconnect-
ing means cannot be locked,
securely fasten a prominent
warning device, such as a
tag, to the service panel.
1)
Run 120 VAC, 15 amp (minimum)
circuit electrical power cable from the
service panel to the junction box in
the rough-in plate.
2)
Remove the knock-out and install
the conduit connector on the rough-
in plate hole.
3)
Feed the conduit through the hole
on top of the rough-in plate to the
junction box.
4)
Remove the junction box cover
from the rough-in plate. Connect
black wire to power supply black
wire, white wire to power supply
white wire and green wire to green
wire or bare wire.
5)
Place all wiring connections inside
junction box and re-install on rough-
in plate. Make sure that wires are
secure and that no wires are pinched
between cover and box.
Wiring Diagram
Refer to the wiring diagram packaged
with the liner for more information.
Step 7: Install Hood Liner Filters
and Drip Cups
1)
Remove all packaging material
from filters and drip cups.
2)
Slide drip cups along bottom edge
of liner opening so lip overhangs
slightly.
3)
Lift filters into place. Lines of filters
must run vertically and align with
drip cups.
4)
Adjust filters to fill space by sliding
filters left to right.
2"
2
1/2
"
2
1/2
"
Electric Placement
WARNING
This ventilation hood liner
must be properly grounded.
This unit should be installed
by a qualified electrician in
accordance with all applica-
ble national and local electri-
cal codes.