Power supply
Installation information, power supply
- Isolate the system from the power supply before opening
the casing.
- Pivot the control unit to the side.
- Open the terminal box.
- Insert the strain relief into the holes provided.
- Strip approx. 70 mm off the power supply cable insulation.
- Push the cable through the strain relief and secure the strain
relief.
- Pull the Rast5 plugs.
- Terminate the appropriate cores at the Rast5 plugs.
- Push the inserts back into the terminal box casing.
- Push the Rast5 plugs back into their correct positions.
Strain relief
F 3,15 A
Rast5 plugs
General notes
The power supply terminals are ‚live‘ even when
the ON/OFF switch has been switched OFF.
The installation must be carried out by a licensed
electrical contractor. Observe local regulations
and those of the power supply company.
Terminal box
The control, regulating and safety equipment are fully wired
and tested.
You only need to connect the power supply and the external
accessories.
Mains electrical connection
Connect the power supply permanently or with a safety plug
(no plug connection in protective areas 1 and 2, i.e. near a
bath or shower).
Provide the power supply via a mains isolator (e.g. fuse, heating
system emergency stop), which ensures at least 3 mm contact
separation for all poles.
Flexible connecting cable, 3 x 1.0 mm² or solid cable, max.
3 x 1.5 mm².
The plug must be accessible when using a power supply cable
with safety plug. Flexible power supply cable 3 x 1.0 mm².
Power supply
230 V AC/50Hz
Power supply, ext. accessories
230 V AC/50Hz/max. 300 VA
Programmable
output
230 V AC/50Hz
Programmable
input zero volt Outside
temp.
sensor
Data BUS
(controller, radio clock, AF with radio
clock, receiver, outside radio sensor)
Terminal box