WIRING PLATE POSITION

DUCTING OPTIONS

BLOWER DISCHARGE POSITIONS

Wiring plate mounts to side or top of housing.

HORIZONTAL POWER

CABLE CONNECTION

VERTICAL

POWER

CABLE

CONNECTION

Ventilator shown in

horizontal discharge

position. (Factory shipped)

DUCT

CONNECTOR

(intake)

Ventilator shown in

vertical discharge position.

(Change movable panel to

new location as shown.)

MOVABLE

PANEL

DUCTING

(Vertical blower discharge)

Typical ductwork connection to a ventilator converted to

vertical discharge.

ROOF CAP

10” ROUND

DUCT

MOVABLE

PANEL

(Change to this

location)

8” X 12” TO

10” ROUND TRANSITIONS

DUCT

CONNECTOR

(outlet)

DUCT

CONNECTOR

(intake)

DUCT

CONNECTOR

(outlet)

Housing

rotated &

movable panel

covers previous

open side.

10” ROUND

DUCT

WIRING

PLATE

WHITE

TO

WHITE

BLACK

TO

BLACK

EDGE

OF HOUSING

120 VAC LINE IN

(from range hood)

GROUND TO

WIRING PLATE

Ventilator can be wired from outside of housing.

Use UL approved connectors to wire per local codes.

;;;;;;;;;

yyyyyyyyy

18"

1½"

to

2½"

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

yyy

yyy

;;

@@

;;

@@

;;

@@

;;

@@

;;

@@

;;

@@

;;

yy

;;;;;;;;;

yyyyyyyyy

18"

1½"

to

2½"

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

yyy

yyy

;;

@@

;;

@@

;;

@@

;;

@@

;;

@@

;;

@@

;;

yy

;;;

yyy

;;;

yyy

22"

;

y

;;;

yyy

22"

1

1

/

8

"

MAX.

MOUNTING OPTIONS

Mounting brackets in

factory-shipped position -

mounted directly to joists.

(Outlet parallel to joists.)

(New construction)

¼-20 hex nuts secure mounting brackets to housing. Loosen and

re-tighten or remove and replace nuts as necessary for desired

mounting bracket position.

Mounting brackets flipped

over and mounted to

additional framing.

(Outlet perpendicular to joists.)

(New or Existing construction)

Factory-Shipped

Straight-Through

Discharge

Factory-Shipped

Straight-Through

Discharge

Housing

Converted to

Right-Angle

Discharge

Mounting brackets flipped

over and mounted to

additional framing.

(Outlet vertical.)

(New or Existing construction)

Mounting brackets flipped

over and mounted to top of

housing. Housing secured

with cables.

(Outlet parallel to joists.)

(New or Existing construction)

Factory-Shipped

Straight-Through

Discharge

WIRING

Summary of Contents for 808332

Page 1: ...e Pepper corn Beef Flambe 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOW ING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off th...

Page 2: ...xisting Frame Construction Factory shipped unit installed in existing construction ACCESS PANEL SCREW 10 ROUND DUCT OUTLET Ventilator factory shipped in straight through discharge position MOUNTING BRACKETS 8 X 12 TO 10 ROUND TRANSITIONS CEILING JOIST 24 centers shown ACCESS PANEL 10 ROUND DUCT INTAKE GRILLE NUT Install into square holes in housing IMPORTANT Removeshippingtapefromdamper Remove the...

Page 3: ...TE Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes yyyyyyyyy 18 1 to 2 yyy yyy yy yyyyyyyyy 18 1 to 2 yyy yyy yy yyy yyy 22 y yyy 22 11 8 MAX MOUNTING OPTIONS Mounting brackets in factory shipped position mounted directly to joists Outlet parallel to joists New construction 20 hex nuts secure mounting brackets to housing Loosen and re tighten or r...

Page 4: ...ower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Follow wiring instructions packed with range hood and adhere to all local and state codes...

Page 5: ...e graisse sur le ventilateur ou sur le filtre 4 Utiliser une casserole de grosseur appropriée Toujours utiliser une batterie de cuisine proportionnelle à l élément de surface AFIN DE DIMINUER LES RISQUES DE BLESSURES POUVANT SURVENIR LORSQU UN FEU SE DÉCLENCHE SUR LA SURFACE DE CUISSON SUIVEZ CES DIRECTIVES 1 ÉTOUFFEZ LES FLAMMES avec un couvercle hermétique une tôle à bis cuits ou un plateau en m...

Page 6: ...soufflerie dans ligne SUPPORTS PANNEAU D ACCESS SUPPORTS préassemblés pour plafonds de po 1 27 cm d épaisseur Soufflerie préassemblée en position de décharge de soufflerie droit angle CONDUIT CIRCULAIRE DE 10 po 25 4 cm sortie TRANSITIONS DE 8 x 12 po au 10 po circulaire 20 3 x 30 5 cm au 25 4 cm circulaire CONDUIT CIRCULAIRE DE 10 po 25 4 cm prise VIS DE PANNEAU D ACCESS CONDUIT CIRCULAIRE DE 10 ...

Page 7: ...es connecteurs homologués UL pour les branchements conformément aux codes locaux en vigueur CÂBLAGE PLAQUE DE CÂBLAGE NOIR AU NOIR BLANC AU BLANC DESSUS ARRIÈRE DU BOÎTIER ENTRÉE 120 VCA du le hotte FIL DE TERRE À PLAQUE DE CÂBLAGE yyy yyy 22 yyyyyyyyy 18 1 to 2 yyy yyy yy y yyy 22 11 8 MAX OPTIONS DE MONTAGE Des écrous à six pans 20 fixent les supports au boîtier Desserrer et resserrer ou retirer...

Page 8: ...erie Retirer la panneau d access débrancher la soufflerie du boîtier retirer les écrous de fixation de la soufflerie et retirer délicatement la soufflerie du boîtier Utiliser un accessoire d aspirateur approprié ou retirer la grille et nettoyer à l aide d un chiffon doux et de savon ou de détergent doux pour nettoyer la zone de décharge de la soufflerie et la roue NE PAS LAISSER D EAU S INFILTRER ...

Reviews: