Overload cool down times
The cooling times represent an overview of the times after which the thermal capacity of the
MOTUS®C14 reaches a certain value when the device has been switched off by overload.
The thermal capacity represents a modelling of the thermal load of the motor.
The "overload" error can only be acknowledged when the value of the thermal capacity has
fallen below 75 %.
Figure 20
Cool down times
Table 3:
Cool down times [hh:mm:ss]
Therm. C.
TC 2E
TC 3E
TC 5
TC 10A
TC 10
TC 20
TC 30
TC 40E
100
– 75 %
00:00:42 00:01:10 00:02:06 00:02:48 00:03:44 00:08:24 00:13:04 00:17:44
100
– 50 %
00:01:41 00:02:48 00:05:04 00:06:44 00:09:00 00:20:14 00:31:28 00:42:42
100
– 25 %
00:03:22 00:05:38 00:10:07 00:13:29 00:17:58 00:40:28 01:02:56 01:25:26
100
– 0 %
00:11:14 00:18:42 00:33:38 00:44:50 00:59:46 01:07:14 01:44:34 02:21:56