RMT-173 Series
I n s t a l l a t i o n R e c om m e n d a t i o n s
Safety Symbols
Installation Recommendations
Heat Dissipation
The ambient temperature around the unit should not exceed 40
°
Celsius (104
°
Fahrenheit). Allow plenty of space around the unit for air
circulation.
Mounting/Bracing
A table top (-TT) stand or rack mount (-RM) kit may be provided. A
standard VESA 100 mounting hole pattern is provided on the back of
the unit for use with other mounts (not supplied).
Refer to
Mounting on page 5
for instructions on attaching the desktop
stand.
Connections and Cable Recommendations
We recommend that you limit the length of the cables that you use for
feeding HD-SDI signals sources to the HD-SDI inputs of the RMT-173
Series units and that you use a Belden 1694A cable (or equivalent). The
HD-SDI inputs (
IN1
and
IN2
) can be up to 150 meters (492 feet) in
length for 1.5 Gbps (HD), more for 270 Mbps (SD) and less for 3Gbps.