Page 24
Unit Configuration
Touching the
Unit Config
selection on the
Unit Settings
Menu proceeds to the
Unit Configuration Menu
. This menu is shown in Figure 2-16.
Figure 2-16: Unit Configuration Menu
Unit Configuration
Right LCD Brightness
Left LCD Brightness
AES Termination
<
>
50
<
>
50
On
Source Knob Selection
<
>
Source Select
Cancel & Exit
Save & Exit
The controls function as follows:
1.
Right LCD Brightness
: This setting adjusts the brightness of the right
display screen, which is used for meter displays and menus. Touch the left
pointing arrow to dim the brightness or touch the right pointing arrow to
increase the brightness.
2.
Left LCD Brightness
: This setting adjusts the brightness of the left display
screen. Touch the left pointing arrow to dim the brightness or touch the right
pointing arrow to increase the brightness.
3.
AES termination
: AES signals should have one and only one termination.
This termination should physically be at the last destination of an AES coax
cable. If the iAM2-8 is the last connection in a series of AES connections,
then its terminations should be turned on. A symptom of too many
terminations (or no termination) is that no signal appears to be present on
the AES input. Touch the
On - Off
switch to change the termination setting.
4.
Source Knob Selection
: This setting determines the function of the
Source
knob on the front panel. It may be set as follows, depending upon your
needs:
a.
Source Select
: The
Source
knob will select the input source to be
monitored.
b.
Cluster Select
: The
Source
knob will select the Loudness Cluster to
be measured.
c.
All Presets
: The
Source
knob will select between any Presets present
in the unit.
d.
No Operation:
The
Source
knob will perform none of the above listed
selection operations. If the
Source
knob is set to
No Operation
and
is turned, the Audio Meters screen will display
for 3