Page 16
To integrate it into your digital network, you need to set its address to the source to
be monitored. You must use the MN-Set configuration software to set up this
option. It is available from Wohler Technologies Technical Service. The procedure to
accomplish this is described in the
SFP-2022-6 / SFP-2110 Setup Guide
(part
number 821822), which is available at
https://wohler.com/downloads/
.
Channel Meters and Touch Operations
The audio mixer terminology of “solo” is used in this manual when referring to
muting all but a specific audio channel or pair.
Audio meters are displayed on touchscreen LCD display(s) in up to 8 channel pairs,
as shown in Figure 2-8.
Figure 2-8: Audio Level Meter Screen
-00
-20
-30
-40
-60
-00
2
1
S
t
e
r
e
o
S
t
e
r
e
o
S
t
e
r
e
o
S
t
e
r
e
o
6
5
8
7
3
LKFS-M : -24.6
-20
-30
-40
-60
SDI-1
4
Channel
Pair Touch
Selection
Area
Channel
Identifiers
Phase Indicators
Loudness
Reading
Loudness Cluster
Marker
Source /
Preset
1.
Channel Identifiers
: Above the level meters are the Channel Identifiers.
They indicate the consecutive channel numbers in the selected source.
An arrow pointing to the left indicates that this is a left channel and
will be monitored in the left speaker.
An arrow pointing to the right indicates that this is a left channel and
will be monitored in the right speaker.
A square indicates that this is a center channel and will be monitored
in both speakers.
This symbol indicates that this channel pair is a Dolby bitstream.
Refer to the Dolby Zoom section of this chapter.
2.
Source/Preset
: This displays the name of the Source or Preset currently
1
2
3
8
7