Operating the Wöhler BC 600 via the app
39
Fig. 31: Roomlist
DIN EN ISO 9972 requires a comprehensible
documentation of the inner volume. Therefore,
when creating or editing the object, you have the
option of creating a room list for which the app
automatically calculates the inner volume.
•
Tap on the building information of the object.
•
Enter the room data.
After you have entered the length, width and
height, the app automatically calculates the area
and volume. The area and height or directly the
volume can also be entered.
The data of the room list is documented in the
PDF report.
•
Tap SAVE
The Customer management menu then opens.
•
To edit a previously created customer file, tap
the Edit icon on the left next to the file.
•
In CUSTOMER MANAGEMENT tap the arrow
(>) in the same line as the customer file (see
Fig. 26) to access the previously created pro-
jects, properties and multi-point tests.
These fields are dimmed (unavailable) prior to the
measurement, so it is not possible to enter any
data.
After the measurement has been completed these
fields are available (highlighted blue). You now
have the option of editing or adding to the details
(except the measurement data) prior to creating
the protocol.
NOTE!
It is possible to create the test report in this view
once the measurement is completed and all data
has been entered (Export report key).