Setting up and dismantling the Wöhler BC 600
26
Fig. 7: Blower fan installed opposite the
door or window hinges
Never install the Wöhler BC 600 in the middle of
the opening, but rather always aligned flush on
the left or the right.
•
First select a suitable installation position for
the Wöhler BC 600. This should be opposite
the door or window hinges.
Fig. 8: Inserting the telescopic rod
•
Insert the telescopic rod into the blower fan so
that it can be extended on the desired side.
Secure the cloth door panel to the
blower fan unit
NOTE!
A zipper facilitates routing the lines through the
panel. This must remain closed during installation
and when carrying out measurements. Irrespec-
tive of the installation situation the panel is always
affixed to the rear of the device housing. That en-
sures the operating unit on the front of the device
remains accessible at all times.
To affix the panel to the blower fan unit proceed
as follows:
•
Pull the fan hole in the panel over the edge of
the blower fan.