GMG-K / GMG-L Operation manual
Page 33 of 58
B0793 / B0796
For both the lower and upper row of elements, different cycle and delivery times as well as
progressive distributor pulses can be set. In case of an overlapping delivery between the
lower and upper element rows, the running delivery will be stopped first. Then, switch-over to
the other row will be made.
The distributor monitoring P7 will be switched on in this mode automatically (when P5 is set
to 1).
P7 will not be reset automatically.
When changing the mode or resetting P5 to 0, the status of P7 needs to
checked and reset manually, if necessary!
Time ON / Lower row distributor pulses OFF / Upper row distributor pulses OFF
variant
(For flow diagram see sub-section 11.3.8)
(Precondition: Monitored progressive distributor in both the lower and upper row of
elements, control C3)
In this setting, the pump unit is switched on within a particular adjustable time for a particular
number of pulses from the monitored progressive distributors. Here, the cycle time means
the time that elapses between the beginning of a delivery interval and the beginning of the
next one.
For both the lower and upper row of elements, different cycle times as well as progressive
distributor pulses can be set. In case of an overlapping delivery between the lower and upper
element rows, the running delivery will be stopped first. Then, switch-over to the other row
will be made.
The P7 and P17 distributor monitoring will be switched on this mode automatically (when P5
and P15 are set to 1).
P7 and P17 will not be reset automatically.
When changing the mode or resetting P5 and P15 to 0, the status of P7
and P17 needs to checked and reset manually, if necessary.
Machine pulses ON / Lower row time OFF / Upper row time OFF variant
(For flow diagram see sub-section 11.3.9)
(Precondition: Control C/C3)
In this variant, the pump unit is switched on for a particular duration (delivery time) when a
specified number of external control pulses is available.
For both the lower and upper row of elements, different numbers of machine pulses and
delivery times can be set. In case of an overlapping delivery between the lower and upper
element rows, the running delivery will be stopped first. Then, switch-over to the other row
will be made.