GMG-K / GMG-L Operation manual
Page 12 of 58
B0793 / B0796
Filling connection
DIN 71412 hydraulic-type lubricating nipple
DIN 3404 button head lubricating nipple
Lock nipple
3.5.4 Level monitoring (option)
The technical data of the (optional) level monitoring unit is as follows:
Supply voltage
24 VDC
Maximum switching current
80 mA
Maximum switching power
1,5 W
Temperature range
-20
… +60 °C
Contact function
PNP opener
When connecting inductive or capacitive loads, the relevant sup-
pressor circuits (diode, RC element, varistor) need to be provided for!
3.5.5 Control
The technical data of the (optional) control is as follows:
Control "C"
Power input
1,7 W
Supply voltage / target
24 VDC
Supply voltage
18
… 30 VDC
Voltage at inputs
24 VDC
Response time of inputs
200 ms
Input resistance
4 k
Ω
Temperature range
-20
… +60 °C
Alarm output
100 mA / 24 VDC / 2 W
Data buffer
10 years