Assembly
32
Options
With the sizes PNG.138 and PNG.V.138 it is possible to monitor
the dynamic pressure of the clamping slide position. Pressure
build-up in "OPENED" status. Control of the clamping slide monitor
requires a reduced pressure supply limited to 2 bar (see chapter
).
The measurable differential pressure must reach a minimum of
0.5 bar in order for a reliable evaluation to be done via the air
gap sensor. The maximum pressure is 2 bar. Monitoring requires
a pressure gauge, an adjustable throttle and an air gap sensor.
For monitoring of the clamping slide, the predefined connection
must be accessed via a base side bore hole.
Request our installation drawings if doing the installation yourself.
PNG.138 / PNG.V.138
4.6
Summary of Contents for 80 809 070
Page 1: ...Original Betriebsanleitung WNT Nullpunktspannsystem PNG PNG SST Montage und Betriebsanleitung...
Page 29: ...Montage 29 PNG SST 6...
Page 40: ...Zusammenbauzeichnungen 40 Zusammenbauzeichnungen PNG 138 PNG T 138 9 9 1...
Page 41: ...Zusammenbauzeichnungen 41 PNG V 138 9 2...
Page 71: ...Assembly 29 PNG SST 6...
Page 82: ...Assembly Drawings 40 Assembly Drawings PNG 138 PNG T 138 9 9 1...