D
is
pl
ay
D
es
cr
ip
ti
on
Ev
en
t
m
em
or
y
D
is
pl
ay
Co
m
m
en
t
in
te
rn
9104 Timer function not possible
√
√ Machine cannot switch
off since cleaning is in
progress
9076 No water pressure
√
√
9118 Fifo was deleted
√
√
9119 Defaults into RAM
√
√
9120 Defaults into Flash
√
√
Milk foamer cleaning in
progress!
√
internal
internal
9136 Cleaning was interrupted
√
√ on account of a
malfunction in the
cleaning program
Display mandatory
cleaning
9236 AD-converter ready!
(For developers only!)
√
√ internal
internal
9248 Electrode malfunction:
PW contact,
but no LW contact
√
√ Check evaluation
settings
9248
9256 Autodetect malfunction:
right grinder not detected
√
√
9256
9257 Autodetect malfunction:
brewing valve not detected
√
√
9257
9258 Autodectect malfunction:
Valve not detected
√
√
9258
9259 Autodetect malfunction:
depressurizing valve not
detected
√
√
9259
9260 Autodetect malfunction:
Fan not detected
√
√
9269
9261 Autodetect malfunction:
Hot water valve not
detected
√
√
9261
9262 Autodetect malfunction:
Mixer or choc valve
not detected, but choc
portioner or vice versa
√
√
9262
9263 Autodetect malfunction:
choc/topping portioner
not detected but mixer
detected
√
√
9263
32
Service manual WMF bistro! Edition 08/2011
WMF bistro! Service manual