D
is
pl
ay
D
es
cr
ip
ti
on
Ev
en
t
m
em
or
y
D
is
pl
ay
Co
m
m
en
t
in
te
rn
131 F131 Current malfunction
hot water valve: current
consumption too high when
valve is addressed.
√
√ Solenoid or wire
defect/short circuit
132 F132 Current malfunction
CW mixing-valve hot
water: current consumption
too high when valve is
addressed.
√
√ Solenoid or wire
defect/short circuit
133 F133 Current malfunction
Brewing valve: current
consumption too high when
valve is addressed
√
√ Solenoid or wire
defect/short circuit
134 F134 Current malfunction
cold water valve: current
consumption too high when
valve is addressed
√
√ Solenoid or wire
defect/short circuit
137 F137 Current malfunction
choc mixer valve: current
consumption too high when
valve is addressed
√
√ Solenoid or wire
defect/short circuit
138 F138 Current malfunction
steam boiler mixer valve:
current consumption
too high when valve is
addressed
√
√ Solenoid or wire
defect/short circuit
140 F140 Current malfunction
steam dispensing valve 1:
current consumption
too high when valve is
addressed
√
√ Solenoid or wire
defect/short circuit
141 F141 Current malfunction
steam dispensing valve 2:
current consumption
too high when valve is
addressed
√
√ Solenoid or wire
defect/short circuit
142 F142 Current malfunction
cappucino valve 1: current
consumption too high when
valve is addressed
√
√ Solenoid or wire
defect/short circuit
143 F143 Current malfunction
cappucino valve 21: current
consumption too high when
valve is addressed
√
√ Solenoid or wire
defect/short circuit
30
Service manual WMF bistro! Edition 08/2011
WMF bistro! Service manual