3.9.3
Service
Customer
All settings in the service memory are loaded into the
customer memory.
Use this option only in exceptional cases. Counters,
grinder correction values, and all beverage settings and
button allocations are loaded, overwriting the current
values.
3.9.4
Customer
Service
Once the customer has accepted the settings, e.g., after
setup, the settings should be loaded into the service
memory.
3.9.5
Factory
Service/Customer
The machine performs the self-test and automatically
detects the 24 V components. The subsequent menus are
pre-configured accordingly.
Factory
Menu Service/Customer menu 1
Heater power
Low water pressure
Mobile station
Heater capacity
is set manually. This affects boiler supply
control and the allowed heating time.
Low water pressure
is set manually. The pump sucks in the
supply water and also fills the boiler.
Mobile station
is set manually. Only in connection with an
external pump controlled by the machine.
see Startup chapter
The heating power must
correspond to the installed
heating-element and the type
plate.
13
Service manual WMF bistro! Edition 08/2011
WMF bistro! Service manual