User Manual WMF 5000 S
Appendix: Technical data
these specifications for the electrical connection and the standards quoted
apply for connecting the coffee machine in EU countries. it may be necessary
to also observe additional country-specific regulations. outside the EU
countries acceptance of the standards quoted is to be checked by the legal
entity or natural person who wishes to use the coffee machine.
The local power supply must be constructed according to the currently valid
IEC 364 (DIN VDE 0100). An isolated ground socket or a country-specific
single-phase socket for single-phase connection, or a 5-pole CEE / CEKON socket
per EN 60309 or a country-specific multi-pole socket for a three-phase connection,
must be available near the machine. The sockets are part of the customer‘s on-site
installation. The mains cable must not come into contact with hot surfaces. If the
mains cable for this device is damaged then it must be replaced by our service
personnel or a similarly qualified person, in order to prevent hazards.
In order to avoid possible faults from arising on our shielded data lines due to
potential equalisation currents between the devices, an additional potential
equalisation unit should be planned for devices connected to the vending system.
(See EN 60309)