28
Original operation manual
AIRCOMBI
AirCombi_BAoDB_en_1701 • rs
Transport, installation and assembly
4.3.1 Mounting the wall bracket (optional)
The machine can optionally be mounted on
a wall bracket.
5 holes with a diameter of 8.5 mm are
provided for fixing the wall bracket. Observe
the weight of the machine (see Technical
data) and select suitable fastening materials,
taking into account the wall structure.
Ensure a sufficient distance between suction
elbow and floor of at least 10 cm.
Fig. 20
: Mounting the wall bracket
Floor
min. 10 cm
4.3.2 Assembling spray hose and atomizer air hose
WARNING
If the hose couplings are subjected to tensile load, these assemblies may
shear off. Material escaping under high pressure can cause injuries and
material damage.
➤
Do not use the hoses for lifting or pulling the device.
WARNING
Components that do not comply with the maximum permitted operating
pressure of the machine can burst and cause serious injury.
➤
Check the maximum permitted operating pressure of the material
hose and the spray gun before assembly. It must be greater than or
equal to the maximum operating pressure of the machine as specified
on the type plate.
Only use conductive material hoses. All original material hoses from
WIWA
are conductive and perfectly adapted to our equipment.
1.
Connect the atomizer air hose (blue):
➤
to the connection for atomizer air on the dual air pressure regulator
➤
to the air inlet of the secured spray gun
2.
Connect the spray hose (black):
➤
to the material outlet of the high pressure filter
➤
to the material inlet of the secured spray gun