Original operation manual
2K GEL UNIT
11
2KGel_14025_25015_BAoDB_en_1701 • rs
Safety
2.4 Safety features
WARNING
If safety feature is missing or is not fully functional, the operating safety of
the machine is not guaranteed!
➤
Put the machine out of operation immediately if you detect safety feature
defects or any other faults on the machine.
➤
Only put the machine back into operation once the faults have been fully
rectified.
The machine is equipped with the following safety features:
➤
Safety valve on proportioning pump and flush pump
➤
Compressed air shut-off valve
➤
Ground cable
Check the safety features on the machine:
➤
Prior to commissioning,
➤
Always prior to starting work,
➤
After all set-up work,
➤
After all cleaning, maintenance, and repair work.
Checklist on the pressureless machine:
5
Seal on the safety valve OK?
5
Safety valve externally free of damage?
5
Function of the compressed air shut-off valve OK?
5
Function of the ball valves and the one-hand lever on the mixer block OK?
5
Ground cable free of damage?
5
Is the ground cable connected to the machine and OK at the circuit board?
Checklist on the pressurized machine:
5
Function of the safety valve(s) OK?
When checking additional safety features, observe the operation manuals for
the optional accessories.