7. ADDITIONAL
FEATURES:
Input Counters
These inputs can be programmed to count active high
pulses. It needs to be activated by SMS to start
counting.
Turn On (Activate) Input 1 -
*CTR1#1
Turn On (Activate) Input 2 -
*CTR2#1
Turn Off (Deactivate) Input 1 -
*CTR1#0
Turn Off (Deactivate) Input 2 -
*CTR2#0
Acquiring All Input Counters Value
*COU?#
Reset Sub Counter
Reset Sub Counter for Input 1 -
*CLC1#
Reset Sub Counter for Input 2 -
*CLC2#
Reset Total Counter
Reset Total Counter for Input 1 -
*CLA1#
Reset Total Counter for Input 2 -
*CLA2#
Setting Counter Alert Value for Inputs
Every counter will increment until it reaches the alert
value, and an alarm will be sent for that input. It can
be set up to a maximum value of 65535 times.
Setting Counter Alert Value for Input 1
-
*COA1#XXXXX
Setting Counter Alert Value for Input 2
-
*COA2#XXXXX
XXXXX
stands for 5 digits counter alert value.
Acquiring All Input Counters Alert Value
*COA?#
Inputs Alarm
These inputs can be programmed by SMS to alarm
when it triggered.
Turn On the Alarm of Input 1 -
*ALM1#1
Turn On the Alarm of Input 2 -
*ALM2#1
Turn Off the Alarm of Input 1
-
*ALM1#0 (Default)
Turn Off the Alarm of Input 2
-
*ALM2#0 (Default)
Acquiring the Status of Alarm
*ALA?#
Setting the Alarm Time Value
The alarm time value can be set up to maximum
value of 65535 seconds
*ALTM#XXXXX
XXXXX
stands for 5 digits value in seconds
Acquiring the Alarm Time Value
*ALT?#
Sound the Alarm Manually
Sound the Alarm -
*ALNF#1
Switch off the Alarm -
*ALNF#0
Functions of I/O (Pin 1)
When switched on, this I/O (Pin 1) can function as Input Counter and will only counts when it short circuit to
ground. When it is switched off, this I/O will function as Output and it can send out active high pulse.
Switch ON the function of I/O -
*CODI#1
- I/O port will function as Input counter.
- It can count when short circuit up to maximum 999 and displays the counter on the screen.
- The counter value will be kept until this function is turned OFF.
Switch OFF the function of I/O -
*CODI#0 (Default)
- I/O port will function as Output.
- When AC power off, it can send out an ALWAYS high pulse.
- It is able to send out active high pulse when used *CTC1#5 or *CTC2#5