Electrical installation
j
| BA 14.0197 | 11/2010
32
5.1.2
Circuit proposals
BFK464XX_1−006.iso
Fig. 14
INTORQ BFK464 connection diagram
Switch−on
|
K2/K4 must be switched
before
or
at the same time as
K1/K3!
Switch−off
|
Normal − AC switching
– K2/K4 remain closed
– K1/K3 open
|
Emergency stop − DC switching
– K1/K3 and K2/K4 are opened at the same time
5.2
Bridge/half−wave rectifiers (option)
BEG−561−
\\\
−
\\\
Bridge/half−wave rectifiers are used for the supply of electromagnetic spring−applied DC
brakes which have been released for operation with such rectifiers. Any other use is only
permitted with the explicit written approval of INTORQ.
After a defined overexcitation time, the bridge/half−wave rectifiers change from bridge
rectification to half−wave rectification. Depending on the dimensioning of the load, the
switching performance can thus be improved or the power can be derated.