![WITTUR sematic SDS Rel. 3 Instruction Manual Download Page 33](http://html1.mh-extra.com/html/wittur/sematic-sds-rel-3/sematic-sds-rel-3_instruction-manual_990289033.webp)
33
www
.wittur
.com
© WI
TTUR • All rights r
eser
ved
PM.2.004921.EN - 808-001-000 SDS
©
rel 3 · Edition 22 July 2020
Drive - Instruction Manual
7 TRIAL OPERATIONS BEFORE START UP THE DOOR CONTROLLER
To avoid damages, check that the power supply voltage be within the rated values before starting up the door controller
Before the lift goes in operation, a self-learning cycle must be carried out and parameters must be set according to the General Options.
7.1 SELF-LEARNING CYCLE
The self-learning cycle allows the Door Controller to store the running distance between the closing and opening limit. It can only
be activated manually and must be carried out under direct supervision of maintenance personnel so that they may check that the
operation is correctly completed (i.e. the Door Controller must store the correct data). The self-learning cycle is shown on the door
controller display with “SL”.
Important!
•
During the self-learning cycle please check carefully that the door panels slide freely and that the Door Operator completes its total
expected travel. The self-learning cycle is essential if a replacement Door Controller has been installed.
•
If a car door locking device is installed the self-learning cycle must be carried out with the operator coupled to a landing door.
Outside the lock release zone of the landing doors, this device prevents the car door opening.
•
Every time the system is re-powered (for instance after power supply interruption) it performs a reset cycle, i.e. it searches a
closing limit at low speed, not a self-learning cycle.
7.2 SELF-LEARNING CYCLE WITH THE DOOR CONTROLLER ONLY (WITHOUT USING THE HANDSET)
•
Power the system
•
Turn on the door controller “ON”
•
For the manual self-learning procedure keep key 4 pressed for a while to switch from automatic to manual mode (check that the
AUTO red led turns off and the MAN red led turns on).
•
To start up the self-learning cycle keep key 1 pressed for a while, Self Learn.
•
The keys 2, opening, and 3, closing, on the door controller command the opening and closing operations.
When a closing command is given, the Door Controller carries out a closing cycle at low speed (the Door Controller display shows the
sign “SL”) or remains in closed position.
When an opening command is given, the Door Controller carries out an opening cycle at low speed (on the Door Controller display the
sign “SL” flashes). During this operation please check carefully that the operator completes its total expected travel).
At the end of the opening cycle, the self-learning cycle is complete (the sign “SL” disappears and “oP” appears).
Keep key 4 pressed again for a while to activate the automatic mode.
Note
: the Self Learning cycle can also be started with the door drive in automatic mode; the door close and door open signals are sent by the main lift controller.
To enter the Self Learning phase in Automatic mode just keep the key 1 pressed for a while, then let the main lift controller to send door open/door close signals.