The following table contains the available parameters, the relevant codes, the description and the allowed modification range:
Code param. Default
Parameter
Range
Note
00
00
Reversing system choice
00, 01, 02
00-> Internal
01-> External - Moving
02-> External - Parking
01
00
Main Lift Controller Test
00, 01, 02
00-> When moving
01-> Parking
02-> Off
02
00
No MLC signal
00, 01, 02
00 -> Instant Stop
01 -> Low Speed to Stop
02 -> Low Speed Cycle
03
00
MLC Input Alarm
00, 01
00 -> Off
01 -> On
04
00
Kn Input
00, 01, 02
00 -> Default
01 -> Limited door reversal
02 -> Safety edge
05
00
Car door locking device
00, 01
00 -> Off
01 -> On
06
00
Glass doors and heavy doors
00, 01
00 -> Off
01 -> On
07
03
Aux Output Relay
00, 01, 02,
03
00 -> Off
01 -> Gong While opening
02 -> Space percentage
03 -> Alarm signal
08
50
Space Percentage (Percentage of the
available space to operate the AUX
relay)
00...99
00..99% (00 = closing limit)
09
49
Reversing force setting
00...99
110-150 N (110-135 N U.S. version)
10
50
Opening High Speed
01...99
with PC 33=02
11
50
Opening Low Speed
01...99
with PC 33=02
12
80
Opening "comfort"
01...99
with PC 33=02
13
35
Closing High Speed
01...99
with PC 33=02
14
16
Closing Low Speed
01...99
with PC 33=02
15
99
Closing "comfort"
01...99
with PC 33=02
16
-
Not Used
-
17
-
Not Used
-
18
-
Not Used
-
19
01
Fire Fighting Mode
00, 01
00 -> Reversing system Off
01 -> Reversing System reduced sensitivity
20
01
Timeout EOD
00 --> 05
minutes
Opening time on EOD contact
(minutes)
21
00
Protective Device Logic Kn
00, 01
00 -> N/O, on obstruction closed
01 -> N/C, on obstruction open
22
00
Closing Rotation
00, 01
00 -> Clockwise
01 -> Anti-clockwise
23
70
% Partial reopening
01...99
24
00
Smooth reopening
00...01
00 -> Off
01 -> On