- 30 -
GB
Settings COFDM
NonHierarchical mode
(Key code XX41)
only at
Channel A*
Channel B**
OV75M A=channel
476 MHz= input frequency A
479.00=output frequency A,
<1.0e-4=BER, alternating display
OV75M
V1.00
busy
Mode*
Remux,
Remultiplexer mode
NonHier
, NonHierarchical mode (channel A -
one frontend module)
Hier
, Hierarchical mode
OV75M A
V1.00
busy
F-Out*
45-862 MHz,
0.25-MHz steps
loop
=
Loop thru mode,
single
= single mode
Out-Att*
0-16 dB
output level, 1-dB steps
OutConf*
Out-BW*
MUXStat
Sum of selected programmes ch A
MUX on
- displaying status of Remux
5, 6, 7, 8 MHz
=
output bandwidth
Please set all parameters of the DVB-T frontend module
Output settings
auto/on
: auto:COFDMCarrier signal switches off.
On: signal doesn't switch off.
COFDMCa*
COFDMSp*
normal / inverse
COFDMSpectrum
Modules*
Mod-No*
Displaying module number
0-9
Version*
Overflow counter shows the account of "overflows".
Counter reset: press simultaneously
ModVers
QAMMode*
16 QAM 64 QAM, QPSK
type of modulation
DVBT-MPEG
- module - displaying modules
basic unit version,
software version module
undocumented command
Overflow counter
Version
V 1.00
1109012
00...99
Displaying: hard and software version of input modules
A: DVBT
- module
S1.0003
- software version
H1.0000
- hardware version
k-Mode*
2k, 8k
k mode
Guardin*
1/4, 1/8, 1/16, 1/32
Guard intervall
Coderat
1/2, 2/3, 3/4, 5/6, 7/8
Coderate
NIT-Ins
On, off
Network Information Table insertion
NetName
network name
7 digits
off or set HEX code
0 x 0000 Network identifier
F F F F
OrgTsId
NetwId
off or set HEX code
0 x 0000 Transport Stream identifier
F F F F
TsId
A
off or set HEX code
0 x 0000 Original Transport Stream
F F F F Identifier
B
NonHierarchical mode supports
one frontend module ch A
Note:
Settings marked with A
Some SetTopBoxes on the mar-
ket requires additional informa-
tions about NIT to scan correct
Transport Stream.
Available from
COFDM version 11
..
Factory setting: on