O p e r a t i n g I n s t r u c t i o n s
OKTOPUS
®
GLASS-Jack
GL-CC 1200
Technical Documentation
BA 000 257
Page 27 of 28
1. disconnect the battery charger from the power grid,
2. disconnect the battery charger from the battery pack.
LED Display
⇒
The green LED lights up if the battery charger is connected to the power grid.
⇒
The yellow LED flashes quickly during the first charging phase and slower during the
second. At the end of the charging process the yellow LED is permanently illuminated.
For maintenance and in case of breakdown of the charging unit please contact our Service
Team.
The sealed lead-gel battery requires strict adherence to the charging in-
structions!
In order to avoid damage due to deep discharge the batteries of the OK-
TOPUS
®
have to be charged at least every two weeks.
The battery charger has to be protected from spray water and has to be set
up in a way that the air vents and the fan are unobstructed and cannot be
pierced through by pointed objects.