Reference Manual
00809-0100-4160, Rev AB
March 2010
6-3
Rosemount 2160
DISASSEMBLY
PROCEDURES
Remove from Service
Be aware of the following:
•
Follow all plant safety rules and procedures.
•
Isolate and vent the process before removing the 2160 from service.
•
Whenever you remove the 2160, visually inspect the o-rings (if used).
Replace the o-rings if they show any signs of damage, such as nicks or
cuts. If they are not damaged, re-use them.
The flanged 2160 is attached to the process connection by bolts. Remove the
bolts and separate the switch from the process connection. Leave the process
connection in place and ready for re-installation.
The threaded 2160 is attached to the process by a single hex nut process
connection. Loosen the hex nut to separate the switch from the process
connection. Leave the process connection in place and ready for
re-installation.
Remove Terminal Block
Wireless PlantWeb Housing
Remove the battery pack. Loosen the two small screws and pull the entire
terminal block out.
Wireless PlantWeb Terminals
COMM
P/N 00753-9200-0010
Summary of Contents for Rosemount 2160 WirelessHART
Page 2: ......
Page 18: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 1 10...
Page 56: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 3 14...
Page 70: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 5 10...
Page 76: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 6 6...
Page 92: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 A 16...
Page 98: ...Reference Manual 00809 0100 4160 Rev AB March 2010 Rosemount 2160 B 6...
Page 99: ......