SERVICE MANUAL & ICA
10000 AMPHIBIAN FLOATS ON AIR TRACTOR AT-802A
Page 108
Revision U
P/N 1002545
15.1 INSPECTION TIME CHECKLIST
General
Details
25
50
100
Annual
R
T.
LT.
General
Placards
X
Hulls & Struts
Float Installation.
Float exterior – Inspect for damage, wrinkled metal, corrosion, paint loss, etc.
X*
Struts & attach fittings
X
Spreader bars
X
Float Structure (interior)
X
R
etorque aft pylon drag strut bolt per Service
Letter 182
X
Foam Compartment Covers and Seals – Inspect for condition, security operation, and excessive wear
.
X
Pumper
Tube Installation – Inspect for condition,
security
, routing of hoses.
X
W
ater
Rudder System
W
ater Rudder Hinges – Inspect freedom of
rotation.
X*
W
ater Rudder Steering and Retract Systems
– Inspect the following: cables for broken
wire; cable fittings for cable slippage, cracks
and distortion.
Inspect cable pulleys for freedom of rotation, cable guard pins for presence; rigging. Retract for operations check.
X
W
ater Rudder Blades and Posts – Inspect
for damage, security of attachment, corrosion, paint, rigging.
Inspect water rudder bulkhead boots for cracks and wear
.
X
Electrical System Gear and
Probe
Pump and Indicator Light Wiring – Inspect
for chafing, broken or loose terminals and
general condition.
X
Solenoids – Inspect wiring, mounting and general condition.
X
Pressure Switches – Inspect wiring, mounting and general condition.
X
INSPECTION
TIME
INTER
VALS
HOURL
Y
LIMITS
MECHANIC
*I
tems denoted with (*) are considered preventative maintenance checks and can be completed and signed off by
authorized personnel I.A.W. CFR 14 Part 43.3 and 43.7 and Appendix A subpart C, or equivalent CAA regulation