background image

 

Version

 

0.2

1

 

Technical

 

Manual

 

 

Caution:

 

 

This

 

device

 

is

 

using

 

a

 

radio

 

signal

 

that

 

passes

 

through

 

walls,

 

windows

 

and

 

doors.

 

The

 

range

 

is

 

strongly

 

influenced

 

by

 

local

 

conditions

 

such

 

as

 

large

 

metal

 

objects,

 

house

 

wiring,

 

concrete,

 

furniture,

 

refrigerators,

 

microwaves

 

and

 

similar

 

items.

 

On

 

average,

 

the

 

indoor

 

range

 

is

 

approximately

 

30

 

meters.

  

 

Do

 

not

 

expose

 

this

 

product

 

to

 

excessive

 

heat

 

or

 

moisture.

  

 

Prevent

 

long

 

term

 

exposure

 

to

 

direct

 

sunlight.

 

 

Do

 

not

 

attempt

 

to

 

repair

 

this

 

product.

 

If

 

the

 

product

 

is

 

damaged

 

or

 

if

 

you

 

are

 

in

 

doubt

 

about

 

the

 

proper

 

operation,

 

take

 

the

 

product

 

back

 

to

 

the

 

place

 

of

 

purchase.

  

 

Do

 

not

 

clean

 

the

 

product

 

with

 

any

 

liquid.

 

Technical

 

details

 

 

 

 

 

 

 

 

Supporting

 

Command

 

Classes:

 

 

Basic

 

type:

 

BASIC_TYPE_ROUTING_SLAVE

 

Generic

 

type:

 

GENERIC_TYPE_SENSOR_BINARY

 

Specific

 

type:

 

SPECIFIC_TYPE_NOT_USED

 

Listening:

 

False,

 

Z

Wave

 

Lib:

 

4.51

 

 

class:

 

0x30

 

COMMAND_CLASS_SENSOR_BINARY

 

class:

 

0x70

 

COMMAND_CLASS_CONFIGURATION

 

class:

 

0x71

 

COMMAND_CLASS_ALARM

 

class:

 

0x72

 

COMMAND_CLASS_MANUFACTURER_SPECIFIC

 

class:

 

0x80

 

COMMAND_CLASS_BATTERY

 

class:

 

0x84

 

COMMAND_CLASS_WAKE_UP

 

class:

 

0x85

 

COMMAND_CLASS_ASSOCIATION

 

class:

 

0x86

 

COMMAND_CLASS_VERSION

 

class:

 

0x31

 

COMMAND_CLASS_SENSOR_MULTILEVEL

 

class:

 

0xEF

 

COMMAND_CLASS_MARK

 

class:

 

0x20

 

COMMAND_CLASS_BASIC

 

class:

 

0x31

 

COMMAND_CLASS_SENSOR_MULTILEVEL

 

 

Not

 

listening

 

Routing

 

SLAVE

 

Normal

 

operating

 

voltage

 

2x

 

AAA

 

1,5V

 

batteries

 

From

 

2,3

 

to

 

4,0Vdc

 

do

 

not

 

use

 

rechargeable

 

batteries

 

Frequency

 

range

 

ϵϬ

8.42

 

MH z

 

Wireless

 

Range

 

Up

 

to

 

30

 

meters

 

in

 

line

 

of

 

sight

 

Storage

 

temperature

 

5

°

C

 

to

 

+65

°

C

 

Storage

 

humidity

 

10%

 

to

 

70%

 

Operating

 

temperature

 

0

°

C

 

to

 

50

°

C

 

Operating

 

humidity:

 

30%

 

to

 

80%

 

Summary of Contents for iDoorSensor

Page 1: ... successful 7 iDoorSensor is now ready to use 8 Remove the back cover of the magnet and repeat step 2 and 4 with the magnet for mounting it Include or exclude in Z Wave network 1 Make sure your Z Wave controller is in the right operation mode include or exclude 2 When the iDoorSensor is mounted remove it from the back cover as explained in step one of the Mounting instructions 3 Press and hold the...

Page 2: ...SIC_TYPE_ROUTING_SLAVE Generic type GENERIC_TYPE_SENSOR_BINARY Specific type SPECIFIC_TYPE_NOT_USED Listening False Z Wave Lib 4 51 class 0x30 COMMAND_CLASS_SENSOR_BINARY class 0x70 COMMAND_CLASS_CONFIGURATION class 0x71 COMMAND_CLASS_ALARM class 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC class 0x80 COMMAND_CLASS_BATTERY class 0x84 COMMAND_CLASS_WAKE_UP class 0x85 COMMAND_CLASS_ASSOCIATION class 0x8...

Page 3: ...ps Retries The Z Wave range has a range of up to 30 meters in line of sight This signal is not limited to the 30 meter range due to routing the Z Wave message to other nodes in the network This way the range of the Z Wave network can be expanded to 150 meters indoors limit of 4 hops class 0x20 COMMAND_CLASS_BASIC When a door is opened a basic set frame with the value 255 is sent to the associated ...

Page 4: ... mode Mode 3 Z Wave chip is always on to request e g version or manufacturer id If any mode other then 3 that value will be reported after a get but will be handled in SW as mode 1 Param2 3 not used 6 The temperature offset Description A offset for the temperature Default 0x00 Size 2 bytes Param1 2 A signed integer to determine the offset off the temperature Param3 4 not used if a size is other th...

Page 5: ... will go into sleep mode again The wake up interval can be set using the WAKE_UP_INTERVAL_SET command The default value is 0x1C20 7200 sec 2 hour The default node is 0xFF 255 broadcast It is possible to send a wake up notification on user interaction To do this press and hold the tamper switch for 8 seconds When the wake up time is set to 0 a wake up notification is never send periodically only on...

Page 6: ...Even when a configuration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET Parameter 0x...

Page 7: ...try it again 2 Make sure the Tamper switch is mounted correctly 3 The magnet contact is not mounted close enough or on the wrong side of the device Q I have configured a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during conf...

Page 8: ......