background image

 

Version

 

0.2

1

 

Maximum

 

supported

 

nodes

 

per

 

group:

 

5

 

 

Group1:

 

if

 

the

 

internal

 

door

 

contact

 

(magnet)

 

is

 

triggered

 

it

 

sends

 

a

 

Z

Wave

 

frame

 

to

 

every

 

node

 

in

 

this

 

group

 

 

Group2:

 

if

 

the

 

external

 

door

 

contact

 

is

 

triggered

 

it

 

sends

 

a

 

Z

Wave

 

frame

 

to

 

every

 

node

 

in

 

this

 

group

 

if

 

it

 

is

 

configured

 

(see

 

configuration

 

documentation

 

param

 

2:

 

external

 

contact).

 

 

Class:

 

0x80

 

COMMAND_CLASS_BATTERY

 

This

 

class

 

is

 

used

 

to

 

request

 

and

 

report

 

battery

 

levels

 

for

 

a

 

given

 

device.

 

When

 

battery

 

level

 

is

 

lower

 

then

 

20%

 

the

 

Door

 

Sensor

 

will

 

send

 

a

 

battery

 

warning

 

(value

 

255)

 

after

 

every

 

wake

 

up

 

notification.

 

A

 

battery

 

get

 

will

 

report

 

the

 

actual

 

value

 

even

 

if

 

below

 

20

 

%

 

 

class:

 

0x84

 

COMMAND_CLASS_WAKE_UP

 

The

 

Wake

 

Up

 

Command

 

Class

 

is

 

used

 

at

 

battery

operated

 

devices.

 

This

 

class

 

allows

 

the

 

DoorSensor

 

to

 

wake

 

up

 

occasionally

 

to

 

notify

 

others

 

devices,

 

that

 

the

 

DoorSensor

 

is

 

ready

 

to

 

receive

 

commands.

 

After

 

receiving

 

the

 

commands

 

the

 

DoorSensor

 

will

 

go

 

into

 

sleep

 

mode

 

again.

 

The

 

wake

 

up

 

interval

 

can

 

be

 

set

 

using

 

the

 

WAKE_UP_INTERVAL_SET

 

command.

  

 

The

 

default

 

value

 

is

 

0x1C20

 

=

 

7200

 

sec

 

=

 

2

 

hour

 

The

 

default

 

node

 

is

 

0xFF

 

=

 

255

 

(broadcast)

 

 

It

 

is

 

possible

 

to

 

send

 

a

 

wake

 

up

 

notification

 

on

 

user

 

interaction.

 

To

 

do

 

this

 

press

 

and

 

hold

 

the

 

tamper

 

switch

 

for

 

8

 

seconds.

 

 

When

 

the

 

wake

 

up

 

time

 

is

 

set

 

to

 

0

 

a

 

wake

 

up

 

notification

 

is

 

never

 

send

 

periodically,

 

only

 

on

 

user

 

interaction.

  

 

class:

 

0x31

 

COMMAND_CLASS_SENSOR_MULTILEVEL

 

Sensor_multilevel_get

 

The

 

Sensor

 

Multilevel

 

Command

 

Class

 

is

 

used

 

to

 

get

 

a

 

report

 

from

 

the

 

Door

 

Sensor.

 

The

 

returned

 

value

 

is

 

the

 

measured

 

temperatue

 

inside

 

the

 

housing

 

with

 

2

 

decimals.

 

 

class:

 

0x71

 

COMMAND_CLASS_ALARM

 

This

 

command

 

class

 

is

 

used

 

to

 

identify

 

the

 

state

 

of

 

the

 

tamper

 

alarm.

 

The

 

device

 

will

 

send

 

an

 

unsolicited

 

report

 

to

 

the

 

controller

 

if

 

the

 

status

 

is

 

changed,

 

the

 

value

 

0x00

 

will

 

indicate

 

that

 

the

 

tamper

 

is

 

placed

 

correctly

 

on

 

the

 

wall.

 

The

 

value

 

0xFF

 

will

 

indicate

 

a

 

tamper

 

alarm.

 

There

 

are

 

2

 

different

 

alarm

 

types:

 

2:

 

External

 

door

 

contact

 

3:

 

Tamper

 

switch

 

Every

 

other

 

alarm

 

type

 

that

 

is

 

requested

 

will

 

be

 

ignored

 

by

 

application.

 

Summary of Contents for iDoorSensor

Page 1: ... successful 7 iDoorSensor is now ready to use 8 Remove the back cover of the magnet and repeat step 2 and 4 with the magnet for mounting it Include or exclude in Z Wave network 1 Make sure your Z Wave controller is in the right operation mode include or exclude 2 When the iDoorSensor is mounted remove it from the back cover as explained in step one of the Mounting instructions 3 Press and hold the...

Page 2: ...SIC_TYPE_ROUTING_SLAVE Generic type GENERIC_TYPE_SENSOR_BINARY Specific type SPECIFIC_TYPE_NOT_USED Listening False Z Wave Lib 4 51 class 0x30 COMMAND_CLASS_SENSOR_BINARY class 0x70 COMMAND_CLASS_CONFIGURATION class 0x71 COMMAND_CLASS_ALARM class 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC class 0x80 COMMAND_CLASS_BATTERY class 0x84 COMMAND_CLASS_WAKE_UP class 0x85 COMMAND_CLASS_ASSOCIATION class 0x8...

Page 3: ...ps Retries The Z Wave range has a range of up to 30 meters in line of sight This signal is not limited to the 30 meter range due to routing the Z Wave message to other nodes in the network This way the range of the Z Wave network can be expanded to 150 meters indoors limit of 4 hops class 0x20 COMMAND_CLASS_BASIC When a door is opened a basic set frame with the value 255 is sent to the associated ...

Page 4: ... mode Mode 3 Z Wave chip is always on to request e g version or manufacturer id If any mode other then 3 that value will be reported after a get but will be handled in SW as mode 1 Param2 3 not used 6 The temperature offset Description A offset for the temperature Default 0x00 Size 2 bytes Param1 2 A signed integer to determine the offset off the temperature Param3 4 not used if a size is other th...

Page 5: ... will go into sleep mode again The wake up interval can be set using the WAKE_UP_INTERVAL_SET command The default value is 0x1C20 7200 sec 2 hour The default node is 0xFF 255 broadcast It is possible to send a wake up notification on user interaction To do this press and hold the tamper switch for 8 seconds When the wake up time is set to 0 a wake up notification is never send periodically only on...

Page 6: ...Even when a configuration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET Parameter 0x...

Page 7: ...try it again 2 Make sure the Tamper switch is mounted correctly 3 The magnet contact is not mounted close enough or on the wrong side of the device Q I have configured a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during conf...

Page 8: ......

Reviews: