background image

Summary of Contents for iDoorSensor

Page 1: ... successful 7 iDoorSensor is now ready to use 8 Remove the back cover of the magnet and repeat step 2 and 4 with the magnet for mounting it Include or exclude in Z Wave network 1 Make sure your Z Wave controller is in the right operation mode include or exclude 2 When the iDoorSensor is mounted remove it from the back cover as explained in step one of the Mounting instructions 3 Press and hold the...

Page 2: ...SIC_TYPE_ROUTING_SLAVE Generic type GENERIC_TYPE_SENSOR_BINARY Specific type SPECIFIC_TYPE_NOT_USED Listening False Z Wave Lib 4 51 class 0x30 COMMAND_CLASS_SENSOR_BINARY class 0x70 COMMAND_CLASS_CONFIGURATION class 0x71 COMMAND_CLASS_ALARM class 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC class 0x80 COMMAND_CLASS_BATTERY class 0x84 COMMAND_CLASS_WAKE_UP class 0x85 COMMAND_CLASS_ASSOCIATION class 0x8...

Page 3: ...ps Retries The Z Wave range has a range of up to 30 meters in line of sight This signal is not limited to the 30 meter range due to routing the Z Wave message to other nodes in the network This way the range of the Z Wave network can be expanded to 150 meters indoors limit of 4 hops class 0x20 COMMAND_CLASS_BASIC When a door is opened a basic set frame with the value 255 is sent to the associated ...

Page 4: ... mode Mode 3 Z Wave chip is always on to request e g version or manufacturer id If any mode other then 3 that value will be reported after a get but will be handled in SW as mode 1 Param2 3 not used 6 The temperature offset Description A offset for the temperature Default 0x00 Size 2 bytes Param1 2 A signed integer to determine the offset off the temperature Param3 4 not used if a size is other th...

Page 5: ... will go into sleep mode again The wake up interval can be set using the WAKE_UP_INTERVAL_SET command The default value is 0x1C20 7200 sec 2 hour The default node is 0xFF 255 broadcast It is possible to send a wake up notification on user interaction To do this press and hold the tamper switch for 8 seconds When the wake up time is set to 0 a wake up notification is never send periodically only on...

Page 6: ...Even when a configuration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET Parameter 0x...

Page 7: ...try it again 2 Make sure the Tamper switch is mounted correctly 3 The magnet contact is not mounted close enough or on the wrong side of the device Q I have configured a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during conf...