Wintop iDoorSensor Quick Start Manual Download Page 4

 

Version

 

0.2

1

 

Read

 

more

 

in

 

chapter

 

Configuration

 

Reset.

 

Size:

  

1

 

byte*

 

Param1:

 

 

 

if

 

0xFF

 

then

 

set

 

to

 

default

 

Param2,3,4:

 

not

 

used

 

 

2.

 

External

 

contact

 

 

 

Description:

 

 

 

Configure

 

what

 

the

 

external

 

contact

 

sends

 

when

 

trigger

 

Default:

 

 

 

0x00

 

(send

 

alarm

 

report)

 

 

Size:

 

 

 

 

1

 

byte*

 

Param1:

 

 

 

if

 

0x00:

  

Send

 

a

 

alarm

 

report

 

with

 

type

 

2

  

If

 

0x01

 ‐ 

0xFF:

 

Send

 

a

 

Basic

 

set

 

frame

 

to

 

all

 

nodes

 

in

 

association

 

group

 

2.

 

3.

 

Not

 

used

 

Description:

 

Is

 

not

 

used

 

but

 

still

 

can

 

be

 

set

 

and

 

requested.

 

Size:

 

 

 

 

1

 

byte*

 

 

4.

 

Not

 

used

 

Description:

 

Is

 

not

 

used

 

but

 

still

 

can

 

be

 

set

 

and

 

requested.

 

Size:

 

 

 

 

1

 

byte*

 

 

5.

 

The

 

mode

 

Description:

 

 

 

the

 

operating

 

mode.

 

 

 

 

Default:

 

 

 

0x01

 

 

 

Size:

    

 

 

1

 

byte*

 

Param1:

 

Mode

 

1:

 

Normal

 

operating

 

mode.

  

Mode

 

3:

 

Z

Wave

 

chip

 

is

 

always

 

on

 

to

 

request

 

e.g.

 

version

 

or

 

manufacturer

 

id.

 

If

 

any

 

mode

 

other

 

then

 

3,

 

that

 

value

 

will

 

be

 

reported

 

after

 

a

 

get

 

but

 

will

 

be

 

handled

 

in

 

SW

 

as

 

mode

 

1.

  

Param2,3:

 

 

 

not

 

used.

 

 

6.

 

The

 

temperature

 

offset

 

Description:

 

 

 

A

 

offset

 

for

 

the

 

temperature.

   

 

 

Default:

 

 

 

0x00

 

 

 

Size:

    

 

 

2

 

bytes*

 

Param1,2:

 

  

 

A

 

signed

 

integer

 

to

 

determine

 

the

 

offset

 

off

 

the

 

temperature.

 

Param3,4:

 

 

 

not

 

used

 

 

*

 

if

 

a

 

size

 

is

 

other

 

then

 

given

 

size

 

the

 

frame

 

is

 

ignored

 

totally

 

so

 

configuration

 

values

 

are

 

not

 

changed

  

 

class:

 

0x85

 

COMMAND_CLASS_ASSOCIATION

 

The

 

Association

 

Command

 

Class

 

is

 

used

 

to

 

associate

 

other

 

devices

 

with

 

the

 

DoorSensor

.

 

The

 

devices

 

that

 

are

 

associated

 

can

 

be

 

controlled

 

on

 

application

 

level.

  

 

The

 

DoorSensor

 

can

 

be

 

associated

 

into

 

a

 

grouping.

 

If

 

so,

 

the

 

DoorSensor

 

can

 

control

 

other

 

Z

Wave

 

device

 

(does

 

not

 

have

 

to

 

be

 

a

 

controller).

  

 
 

Number

 

of

 

groupings:

 

2

 

Summary of Contents for iDoorSensor

Page 1: ... successful 7 iDoorSensor is now ready to use 8 Remove the back cover of the magnet and repeat step 2 and 4 with the magnet for mounting it Include or exclude in Z Wave network 1 Make sure your Z Wave controller is in the right operation mode include or exclude 2 When the iDoorSensor is mounted remove it from the back cover as explained in step one of the Mounting instructions 3 Press and hold the...

Page 2: ...SIC_TYPE_ROUTING_SLAVE Generic type GENERIC_TYPE_SENSOR_BINARY Specific type SPECIFIC_TYPE_NOT_USED Listening False Z Wave Lib 4 51 class 0x30 COMMAND_CLASS_SENSOR_BINARY class 0x70 COMMAND_CLASS_CONFIGURATION class 0x71 COMMAND_CLASS_ALARM class 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC class 0x80 COMMAND_CLASS_BATTERY class 0x84 COMMAND_CLASS_WAKE_UP class 0x85 COMMAND_CLASS_ASSOCIATION class 0x8...

Page 3: ...ps Retries The Z Wave range has a range of up to 30 meters in line of sight This signal is not limited to the 30 meter range due to routing the Z Wave message to other nodes in the network This way the range of the Z Wave network can be expanded to 150 meters indoors limit of 4 hops class 0x20 COMMAND_CLASS_BASIC When a door is opened a basic set frame with the value 255 is sent to the associated ...

Page 4: ... mode Mode 3 Z Wave chip is always on to request e g version or manufacturer id If any mode other then 3 that value will be reported after a get but will be handled in SW as mode 1 Param2 3 not used 6 The temperature offset Description A offset for the temperature Default 0x00 Size 2 bytes Param1 2 A signed integer to determine the offset off the temperature Param3 4 not used if a size is other th...

Page 5: ... will go into sleep mode again The wake up interval can be set using the WAKE_UP_INTERVAL_SET command The default value is 0x1C20 7200 sec 2 hour The default node is 0xFF 255 broadcast It is possible to send a wake up notification on user interaction To do this press and hold the tamper switch for 8 seconds When the wake up time is set to 0 a wake up notification is never send periodically only on...

Page 6: ...Even when a configuration parameter is changed back to the default value Value 0xAA Devices still has all his factory settings This are only configuration parameters wake up interval can be changed Always awake mode The always awake mode is used to request different values from the device e g version and manufacturer specific The always awake mode can be activated by CONFIGURATION_SET Parameter 0x...

Page 7: ...try it again 2 Make sure the Tamper switch is mounted correctly 3 The magnet contact is not mounted close enough or on the wrong side of the device Q I have configured a value but when I request it it is not changed A It is mandatory that the correct size is used while configure a parameter go to the documentation about the configuration command class to check if the right size is used during conf...

Page 8: ......