12
3A
Solenoid valve (O7) is “sticking” (is constantly open)
Fresh water constantly flowing through the intermediate circuit into the
boiler
Remedy:
Replace solenoid valve.
3B
Inner tube of the coaxial heat exchanger dirty
Remedy:
Clean / replace
3C
I22 temperature sensor defective
Remedy:
Replace temperature sensor kit.
3D
Calcified plate heat exchanger
Remedy:
Descale plate heat exchanger (
7.2).
3E
Lack of refrigerant
Indication:
constant bubbling in the inspection glass
Remedy:
Have repair carried out by experienced refrigeration technician.
3F
Defective thermal expansion valve
Remedy:
Have repair carried out by experienced refrigeration technician.
3
Heat pump is working, but tank temperature cannot reach the rated
temperature