background image

 

12 

Adjusting total hardness 

IMPORTANT

  Before adjusting the total hardness, the manually 

triggered venting must have been done (

 chap-

ter 5). 
During the setting the device must not be in regen-
eration mode. 

 

 Determine the total hardness of the raw water. 

 See the table for the relevant setting value. 

 

 

 
 
 
 

INFO

 

The setting values in the dark columns are directly applied 
to the setting disc (2). 

 

  

 
 

 Press down the setting button (1). 

 Turn the setting button (1) until the arrow (3) points centrally to the 

required setting value in the viewing window. 

IMPORTANT

 

The arrow must not point to the black area. 

INFO

 

Each tooth deviation means 20 litres of softened water 
more or less up until the next regeneration. 

 

 Switch on the warewasher connected to the softener. 

 Fill up the warewasher. 

 Check that the hose connections do not leak. 

 

7 Instructing 

personnel 

 Instruct personnel in the following points: 

 

  Salt refilling 

 

  Maintenance and care 

 

Total hardness  [°dH] 

4 5 6 

8 9 10 

Setting value 

 

1 3  6 

10 11 13 

a [mm] 

5 5 5 

5 5 5 

Softened water 
between 
2 regenerations 

[l] 

1512 1369 1165 1022

879 797 654 

 

Total hardness  [°dH]

11- 

12 

13- 

14 

15 

16-

19 

20-

23 

24-

31 

32-

40 

41-

45 

Setting value 

 

14 15  16 

17 

18 19 20 

20 

[mm]

5 5  5 

5 5 5 

17 

Softened water 
between 
2 regenerations 

[l] 

593 511  450 

368 

307 225 164 164

Summary of Contents for DuoMatik 3

Page 1: ...DuoMatik 3 Operating instructions Connection diagram Commissioning instructions 7 12 GB...

Page 2: ......

Page 3: ...ce and how it functions The softener may only be operated as described in these operating instructions 2 Product description The softener consists of a mobile plastic container and a removable cover T...

Page 4: ...te the softener 5 Operation The softener works automatically following commissioning Only the regeneration salt must be refilled from time to time Caution Possibility of damage due to incorrect salt O...

Page 5: ...preventer 3 audibly suck in air while water is flowing out of the hose 4 Replace the backflow preventer 3 if it does not pass the test Reinstall the backflow preventer 3 according to the connection di...

Page 6: ...nce with DIN EN 1717 National installation and operating regulations must also be complied with The system can also be mounted in mirror image Provide on site connections next to the device 6 Waste wa...

Page 7: ...setting 5 mm Total hardness 40 dH Change distance a to 17 mm INFO The salt consumption per regeneration increases from 0 3 kg to 0 5 kg Ensure that the valve base 1 is sitting in the recess of the co...

Page 8: ...PORTANT The arrow must not point to the black area INFO Each tooth deviation means 20 litres of softened water more or less up until the next regeneration Switch on the warewasher connected to the sof...

Page 9: ......

Page 10: ...9 0 75 42 4 02 1 87 www winterhalter de info winterhalter de Winterhalter Gastronom GmbH Commercial Dishwashing Systems Winterhalterstrasse 2 12 88074 Meckenbeuren Germany Telephone 49 0 75 42 4 02 0...