SYS-405/Specifications
v1.0
www.winsystems.com
Page 5
6. Specifications
The SYS-405 system adheres to the following specifications and requirements.
SYS-405 Specifications
Electrical
V
CC
10 to 50 V DC ±5%, 15 Watts (maximum)
MTBF
14.5 Years
Battery: CR-2032
Chemical System: Li/MnO
2
Nominal Voltage: 3 V
Rated Capacity: 225 mAh
Mechanical
Mechanical Enclosure
Dimensions
8 x 5 x 2.5 inches (203.2 x 127 x 63.5 mm)
Weight
2.65 lbs (1.20 kg)
Environmental
Temperature
-40 °C to +85 °C (-40 °F to +185 °F)
Humidity (RH)
5% to 95% non-condensing
Mechanical Shock
Testing
MIL-STD-202G, Method 213B, Condition A 50g half-sine,
11 ms duration per axis, 3 axis
Random Vibration
Testing
MIL-STD-202G, Method 214A, Condition D .1g/Hz
(11.95g rms), 20 minutes per axis, 3 axis
RoHS Compliant
Yes
Operating Systems
Runs 32/64-bit Windows, Linux, and other x86-compatible operating systems.