WiNRADiO G305 User’s Manual
41
Scanner Configuration
When a signal level is higher than the squelch level, this indicates that a signal
has been found. You can configure the software to specify what action you
want to be taken at this point. To access this configuration facility,
go to
Options | Scanning
in the top bar menu.
Scan Settings
There are two basic actions the software can do when a signal is found:
Pause
scanning or
Stop
scanning. If Pause is selected, then you need to
further specify the conditions under which the scanning will
Resume
. The
conditions to resume can be one of the following:
1. When the signal disappears (i.e. the scanning resumes immediately
when the signal disappears);
2.
After a certain user-defined
Delay time
(i.e. no matter if the signal
disappears during this Delay Time or not, the software will always wait
for the Delay Time interval, then resume);
3. When the signal disappears during
Delay time
(i.e. the scanning will
resume after Delay time, or earlier if the signal disappears);
4. When there is no signal during the
Delay time
(i.e. the scanning will
resume if there is a no-signal gap equal to, or longer than, Delay time)
.