FM08 Product Reference Guide
58
Defroster
In cold storage, outdoor or in intermodal facilities condensation may appear on the screen. A defroster clears
condensation and thaw frost from the screen. Notice that Defroster is an optional feature for the FM08 and may not be
present in your device.
To show the defroster status open Win-Set
and go to the Defroster sub-menu to see the information about the
defroster.
IMPORTANT:
The defroster is always
disabled
when the device is operating from UPS battery power.
Item
Setting
Setting
Options
Default
Setting
Description
1
Defroster
Enabled
Disabled
Enables the defroster.
Disabled
Disables the defroster.
2
Defroster on trip
point
-30 ~ 0°C
Default: -5°C
When enabled, defroster automatically starts
working when the outside temperature drops down
to defroster on trip point (°C)
3
Defroster off trip
point
+5°C, +10°C
Default: +10
°C
When enabled, defroster automatically stop working
when the outside temp. reaches defroster off trip
point (°C)
Press Exit
button to close the Win-Set menu and go back to the desktop.