The IDU doesn’t respond for several
seconds.
This happens when the IDU is not communicating with the
modem.
Verify that the IDU is connected to the proper modem.
Turn the entire system off. Turn the modem on and wait
several seconds before turning the IDU on.
Verify that the IDU is getting the proper DHCP address (or
static address).
“Homing Sequence Needed”
message appears on the IDU
screen.
OR
Dish raises but will not move in
azimuth. This may happen when
calibrating the motors or normal
operation.
This will happen if the antenna loses power while moving or a
possible motor fault.
Try and perform a motor calibration first.
If a motor calibration does not clear the error, enter the debug
menus and try to move the motors individually. See appendix
A.
Determine if any motor indicates an invalid position command.
Verify motor positioning is working through the DC> debug
commands.