www.Wine-Mate.com
PROBLEM
POSSIBLE CAUSES
RESPONSE
Compressor stopping
and starting but
short running time
No cooling but
compressor running
Evaporator icing
House circuit tripping
Noisy operation
a.
b.
c.
d.
e.
f.
g.
h.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
a.
b.
c.
d.
e.
f.
g.
h.
Incorrect temperature setting
Incorrect voltage
Failed thermistor
Failed components
Improper condenser airflow
Dirty condenser
Overcharge of refrigerant
Discharge or suction pressure to high
a.
b.
c.
a.
b.
c.
a.
b.
c.
d.
a.
b.
c.
d.
a.
b.
c.
a.
b.
c.
Evaporator airflow restricted
Refrigerant leakage
Refrigeration system restriction
Set 55 to 60 degrees Farhenheit
Check for voltage
Check thermistor by placing it in ice
water and measuring resistance
Check compressor windings, start relay
and overload protector.
Check for condenser fan
Clean condenser
Call service to remove refrigerant
Call service for OEM information
Check for airflow through evaporator
Check for loss of refrigerant
Call service to check restrictions
Evaporator air flow restricted
Unit not stopping due to air leak, high
ambient temperature or low setting
Low ambient temperature
Bad thermostat or sensor
Refrigerant leaking
Expansion valve blockage
Check for fans
Check for seal, door opening, ambient
temperature and setting
Defrost the unit
Check for thermostat and sensor
Check for sealed system leakage
Check for low side pressure
Incorrect fuse or breaker
Incorrect wirings
Failed components
Check for proper fuse or breaker
Check wirings and connections
Call service
Mounting area not firm
Loose parts
Compressor overloaded due to high
ambient temperatures or airflow
restriction
Malfunctioning components
Add support to improve installation
Check fan blades, bearings, cabinet
washers, tubing contact and loose screws
Check for airflow blockage
Call service to check for inadequate
lubrication, loose and incorrect wirings
25