www.Wine-Mate.com
Code Description
2. Alarm Signals
Probe alarms P1”, start a few seconds after the fault in the related probe; they automatically stop a few seconds after the probe
restarts normal operation. Check connections before replacing the probe. Temperature alarms “HA”, “LA” automatically stops as
soon as the temperature returns to normal value. Alarm “CA” (with i1F=PAL) recovers only by switching off and on the instrument.
3. Set-Temperature
How to see the set-temperature
1. Push and immediately release the SET key: the display will show the Set-point value;
2. Push and immediately release the SET key or wait for 5 seconds to display the probe value again.
How to change the set-temperature
1. Push the SET key for more than 3 seconds to change the Set point value;
2. The value of the set point will be displayed and the “°C” or “°F” LED starts blinking;
3. To change the Set value, push the o or n arrows within 10s.
4. To memorize the new set point value, push the SET key again or wait 10s.
4. Humidity Adjustment
The parameter Fon is used to modulate the humidity in the wine cabinet. The higher value of Fon, the higher relative humidity
will be.
1. Press the Set + keys for 3 sec. (the “°C” or “°F” LED starts blinking).
2. Release the keys, then push again the Set + keys for more than 7sec, the Pr2 label will be displayed immediately followed from
the HY parameter.
3. Select the required parameter Fon by up or down keys .
4. Press the “SET” key to display its value.
5. Use up or down keys to change its value.
6. The default value is 5, change high or low value to maintain high or low humidity.
7. Press “SET” to store the new value.
8. To exit: Press SET + or wait 15sec without pressing a key.
5. Manual Defrost
Push the DEF key for more than 2 seconds and a manual defrost will start.
Alarm Recovery
MESSAGE
CAUSE
OUTPUTS
“P1”
Room probe failure
Compressor output acc. to par. “Con” and “COF”
“HA”
Maximum temperature alarm
Outputs unchanged
“LA”
Maximum temperature alarm
Outputs unchanged
“CA”
Serious external alarm (i1F-bAL)
All outputs OFF
21