40
Mounting the Unit
安装主机
CAUTION
警示
RISK OF PERSONAL INJURY OR DAMAGE TO EQUIPMENT
造成人身伤害或设备损坏危险
Check supporting structure for load bearing capacity to support the Wine Guardian.
All supports must be designed to meet applicable local codes and ordinances.
If in doubt, consult a qualified architect, engineer or contractor.
检查负载支撑结构的承载能力是否可以支持酒卫主机。
所有支持的设计必须符合地方法规和条例。
如有疑问,请咨询合格的建筑师,工程师或承包商。
Note: Review the mounting illustrations on pages 32 and 33 before mounting the unit.
注意:回顾前
32
页,
33
页上机组安装插图。
Floor Mounting
Mount the Wine Guardian on the floor but elevate it on frame with a plywood surface to
keep it away from water. Allow adequate space for the external drain.
地板安装
如果酒卫主机安装在地板上,请使用框架,上面加胶合板,
保持离水。允许足够的排水管空
间。
Wall Mounting
If the unit is mounted through the wall, adequately support it on both sides of the wall. Use
floor or knee braces to transfer the load of the unit to the floor or wall.
壁挂式安装
如果主机是穿墙
安装,墙的两边都要有充分的支撑。使用地板或三角支撑,把主机的重量转
移到地面或墙上。
Ceiling Mounting
Construct a structurally sound, level platform to place the unit on when hanging it from the
ceiling joists. The Wine Guardian is
NOT
designed to be suspended from the top of the unit.
Place the unit on a platform to ensure that the unit is supported on all for corners. Leave ad-
equate space on the top of the unit to remove the access doors for service.
In all cases the unit must be level to /- 6mm end-to-end and +/- 3mm side-to-side for
proper operation. Locate the unit as close to the wine cellar as possible to reduce the length
of the duct runs. If possible, use short and straight ducting on all ductwork. The addition of
6mm thick rubber pads helps prevent the transmission of vibration and noise.
Summary of Contents for D025
Page 19: ...13 D025 D050 D050V WG40 WG75 Wiring diagram for D025 D050 D050V WG40 and WG75...
Page 20: ...14 D025 D050 D050V WG40 WG75 Wiring diagram for D025 D050 D050V WG40 and WG75 cont...
Page 21: ...15 D088 D088V WG100 Wiring diagram for D088 vertical model D088V and WG100...
Page 22: ...16 D088 D088V WG100 Wiring diagram for D088 vertical model D088V and WG100 cont...
Page 23: ...17 D088 D088V WG100 Wiring diagram for D088 vertical model D088V and WG100...
Page 24: ...18 D088 D088V WG100 Wiring diagram for D088 vertical model D088V and WG100 cont...
Page 25: ...19 D200 WG175 Wiring diagram for D200 and WG175...
Page 26: ...20 D200 WG175 Wiring diagram for D200 and WG175 cont...
Page 27: ...21 D025 D050 Wiring diagram for water cooled D025 and D050...
Page 28: ...22 D025 D050 Wiring diagram for water cooled D025 and D050 cont...
Page 29: ...23 D088 D200 Wiring diagram for water cooled D088 and D200...
Page 30: ...24 D088 D200 Wiring diagram for water cooled D088 and D200...
Page 61: ...55 5 6 1 2...
Page 62: ...56 1 2 2 50 F 10 C 3 3 65 F 18 C 4 4 5 5 5 95 6 6 0 0 1 2 5...
Page 63: ...57 7 7 0 0 1 8 8 10 3 5 9 9 1 0 10 10 25 40 39 1...
Page 66: ...60 30 30 1 1 2 2 3 1 4 2 RF 31 31 RF 0 RF 1 12 RF 12 32 39 1 40 40 2 41 41...
Page 67: ...61 3 42 42 4 43 43 44 49 50 50 0 1 51 69 70 70 71 71...
Page 68: ...62 72 72 1 2 3 3 2 5 4 1 1 57...
Page 69: ...63 2 CS 2 CS 3 3 4 4...