CALIFORNIA EVAPORATIVE EMISSION CONTROL

WARRANTY STATEMENT

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board is pleased to explain the evaporative emission control system’s warranty on your model 

2020 generator. In California, new equipment that uses small off-road engines must be designed, built, and equipped 

to meet the State’s stringent anti-smog standards. WINCO must warrant the evaporative emission control system on 

your generator for the period listed below provided there has been no abuse, neglect or improper maintenance of your 

equipment leading to the failure of the evaporative emission control system.

Your evaporative emission control system may include parts such as: carburetor, fuel tank, fuel cap, fuel lines (for liquid fuel 

and fuel vapors), fuel line fittings, fuel line clamps, carbon canisters, and carbon canister mounting brackets.

MANUFACTURER’S WARRANTY COVERAGE

The evaporative emission control system is warranted for two years. If any evaporative emission related parts on your 

equipment are defective, the parts will be repaired or replaced by WINCO.

WINCO warrants to the original purchaser for 36 months or 1000 hours, whichever occurs first, that goods manufactured 

or supplied by it will be free from defects in workmanship and material, provided such goods are installed, operated and 

maintained in accordance with WINCO written instructions and applicable codes. 

WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the 

product. At WINCO’s option, material found to be defective in material or workmanship under normal use and service 

will be repaired or replaced. For warranty service, return the product within the warranty period, to your nearest WINCO 

Authorized Service Center or to WINCO in Le Center Minnesota. 

Duration Consumer, Commercial and Rental

Parts & Labor: 24 Months

Parts Only: 24-36 Months

EXCLUSIONS:

•   Normal maintenance consumables or labor.

•  This warranty does not cover travel time, mileage or labor for removal or re-installation of WINCO product from its 

 application. 

•  Normal wear and tear.

•  Costs of rental equipment. 

•  WINCO does not warrant engines. Engines are covered exclusively by the warranties of their respective manufacturers. 

•  WINCO does not warrant component parts that are warranted by their respective manufacturers. 

•  WINCO does not warrant modifications or alterations which were not made by WINCO. 

•  WINCO does not warrant products which have been subjected to misuse and/or negligence or have been involved in 

 

an accident. Proof of proper maintenance must be furnished upon request. 

THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE NO OTHER 

WARRANTIES, EXPRESSED OR IMPLIED, OR OTHERWISE CREATED, INCLUDING BUT NOT LIMITED TO WARRANTIES OF 

MERCHANTABILITY, OR WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.

WINCO is liable for the repair or replacement of the product only and is not liable for incidental or consequential damages 

as permitted by your state. This warranty gives you specific legal rights which may vary from state to state. 

ENGINE GENERATOR SET 

36 MONTH 

LIMITED WARRANTY

Summary of Contents for WL22000VE

Page 1: ...to contact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCH...

Page 2: ...ESHOOTING 17 RECEPTACLE WIRING DIAGRAM 18 WL22000VE B RECEPTACLE WIRING DIAGRAM 19 WL22000VE C CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important in...

Page 3: ...mixed with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back into close...

Page 4: ...r AME3 Part Number 16346 031 Rotor Resistance 9 743 Ohms 20 C Stator Resistance 0 366 Ohms 20 C Exciter Rotor Resistance 1 453 Ohms 20 C Exciter Stator Resistance 15 71 Ohms 20 C AVR DSR ENGINE Engine...

Page 5: ...e performance these units should never be run in small compartments without positive fresh air flow RESTRICTED USES DO NOT remove from the cradle assembly Removal of the generator from the cradle asse...

Page 6: ...ess take about the same amount of current to run them whether they are Repulsion Induction RI Capacitor Cap or Split Phase SP type If the electric motor is connected to a hard starting load such as an...

Page 7: ...re you check or add oil to the system The necessity of using the correct oil and keeping the crankcase full cannot be overemphasized Engine failures resulting from inadequate or improper lubricant are...

Page 8: ...safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the Bat terminal Make sure all connections are clean an tight Reverse the sequenc...

Page 9: ...asoline is blended to improve starting Do not use summer grade gasoline 2 HOT WEATHER A Use the proper oil for the temperature expected B Use only summer blended gasoline Using gasoline left over from...

Page 10: ...f your generator is application dependent Carefully evaluate your planned use of your generator to understand which grounding you require If you are not sure what to do contact a competent professiona...

Page 11: ...60 to 100 Amp entrance service much greater than the capacity of this portable generator When installing the generator at these sites a secondary emergency distribution panel may have to be installed...

Page 12: ...T Generator Load Speed RPM Frequency Hz Voltage 120V Recpt 240V Recpt None 3690 61 5 120V 240V Half 3600 60 0 120V 240V Full 3510 58 5 120V 240V The speed of the engine was carefully adjusted at the f...

Page 13: ...e YourGen meter will light up the oil icon and the word change will flash Once the oil has been changed press and hold the cycle button for approximately 5 seconds until the warning has been removed f...

Page 14: ...e air filter and secure with the retainer D and fastener C 10 Install the cover B and secure with the fastener A Ensure the fastener is tight SPARK PLUG Replace annually or every 300 hours of operatio...

Page 15: ...15 OPM 140 E CARBON CANISTER Designed to collect store and dispose of fuel vapors created in the fuel tank fuel system The canister should last the life of the unit as long as it stays dry...

Page 16: ...sing damaged or cracked receptacles can be both dangerous to the operator and destructive to the equipment CLEANING Remove dirt and debris with a cloth or brush DO NOT use high pressure spray to clean...

Page 17: ...stator Defective rotor field Defective AVR Circuit breaker trips Defective load Defective receptacle Excessive load Voltage too high Engine speed is too high Generator overheating Overloaded Insuffic...

Page 18: ...18 OPM 140 E G1 N N N N N N N N N GND GND GND GND GND GND G2 G2 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 RECEPTACLE WIRING DIAGRAM WL22000VE B...

Page 19: ...19 OPM 140 E LOOM TO GENERATOR GREEN LEAD N N N N N N N N N GND GND GND GND GND GND G1 G1 G1 G2 G2 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 G1 G1 RECEPTACLE WIRING DIAGRAM WL22000VE C...

Page 20: ...medy for a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use and service will be re...

Reviews: