SAFETY

This engine generator set has been designed and 

manufactured to allow safe, reliable performance. Poor 

maintenance, improper or careless use can result in 

potentially deadly hazards; from electrical shock, exhaust 

gas asphyxiation, or fire. Please read all safety instructions 

carefully before installation or use. Keep these instructions 

handy for future reference. Take special note and follow all 

warnings on the unit labels and in the manuals.

CALIFORNIA PROPOSITION 65

WARNING: This product contains crude oil, 

gasoline, diesel fuel and other petroleum 

products, Antifreeze to which can expose you 

to chemicals including toluene and benzene, 

Ethylene glycol (ingested) which are known to the 

State of California to cause cancer, birth defects or 

other reproductive harm and developmental issues. 

For more information go to www.P65Warning.ca.gov.

SAFETY DEFINITIONS

DANGER

Indicates an imminently hazardous situation 

which, if not avoided, will result in death or 

serious injury. 

WARNING

Indicates a potentially hazardous situation 

which, if not avoided, could result in death 

or serious injury.

CAUTION

Indicates a potentially hazardous situation 

which, if not avoided, may result in minor or 

moderate injury. It may also be used to alert 

against unsafe practices.

DANGER: ELECTRICAL SHOCK 

The output voltage present in this equipment can cause 

fatal electric shock. This equipment must be operated by a 

responsible person.

  A. Do not allow anyone to operate the generator 

   without 

proper 

instruction.

  B. Guard against electric shock.

  C. Avoid contact with live terminals or receptacles.

  D. Use extreme care if operating this unit in rain or 

   snow.

  E. Use only three-pronged grounded receptacles 

   and 

extension 

cords.

  F. Be sure the unit is properly grounded for your 

   application.

DANGER: DEADLY EXHAUST GAS

Exhaust fumes from any gasoline engine contain carbon 

monoxide, an invisible, odorless and deadly gas that must 

be mixed with fresh air.

  A. Operate only in well ventilated areas.

  B. Never operate indoors including attached 

   garages

  C. Never operate the unit in such a way as to allow 

      exhaust gases to seep back into closed rooms 

      (i.e. through windows, walls, floors).

WARNING: FIRE HAZARD

Gasoline and other fuels present a hazard of possible 

explosion and/or fire.

  A. Do not refuel when the engine is running or hot.

  B. Keep fuel containers out of reach of children.

  C. Do not smoke or use open flame near the 

      generator set or fuel tank.

  D. Keep a fire extinguisher nearby and know its 

      proper use. Fire extinguishers rated ABC by 

   NFPA 

are 

appropriate.

  E. Store fuel only in an approved container, and 

      only in a well ventilated area.

  F. Follow local codes for closeness to combustible 

   material.

CAUTION: PERSONAL INJURY

The muffler becomes very hot during operation and for a 

period after the unit has been turned off. Do not touch the 

muffler until it has completely cooled off.

CAUTION: NOISE HAZARD

Excessive noise is not only tiring, but continual exposure 

can lead to loss of hearing.

  A. Use hearing protection when working around 

      this equipment for long periods of time.

  B. Keep your neighbors in mind when using this 

   equipment.

CAUTION

Keep the generator and surrounding area clean.

  A. Remove all grease, ice, snow or materials that 

   create 

      slippery conditions around the unit.

  B. Remove any rags or other materials that could 

      create a potential fire hazard.

  C. Carefully clean up any gas or oil spills before 

   starting 

the 

unit.

CAUTION

All service, including the installation or replacement of 

service parts, should be performed only by a qualified 

technician.

  A. Use only factory approved repair parts.

  B. Do not work on this equipment when fatigued.

  C. Never remove the protective guards, covers, or 

      receptacle panels while the engine is running.

  D. Use extreme caution when working on electrical 

      components. High output voltage from this 

      equipment can cause serious injury or death.

  E. Always avoid hot mufflers, exhaust manifolds, 

      and engine parts. They can cause severe burns 

   instantly.

  F. The use of the engine-generator set must comply 

      with all national, state, and local codes.

Summary of Contents for WL22000VA

Page 1: ...tact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DA...

Page 2: ...TOR MAINTENANCE CLEANING TROUBLESHOOTING 18 RECEPTACLE WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should...

Page 3: ...20 C Stator Resistance 0 366 Ohms 20 C Exciter Rotor Resistance 1 453 Ohms 20 C Exciter Stator Resistance 15 71 Ohms 20 C AVR DSR ENGINE Engine Manufacturer Briggs Stratton Engine Model Number 613477...

Page 4: ...with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back into closed room...

Page 5: ...e performance these units should never be run in small compartments without positive fresh air flow RESTRICTED USES DO NOT remove from the cradle assembly Removal of the generator from the cradle asse...

Page 6: ...about the same amount of current to run them whether they are Repulsion Induction RI Capacitor Cap or Split Phase SP type If the electric motor is connected to a hard starting load such as an air comp...

Page 7: ...ator must be on a level surface before you check or add oil to the system The necessity of using the correct oil and keeping the crankcase full cannot be overemphasized Engine failures resulting from...

Page 8: ...safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the Bat terminal Make sure all connections are clean an tight Reverse the sequenc...

Page 9: ...asoline is blended to improve starting Do not use summer grade gasoline 2 HOT WEATHER A Use the proper oil for the temperature expected B Use only summer blended gasoline Using gasoline left over from...

Page 10: ...nt Carefully evaluate your planned use of your generator to understand which grounding you require If you are not sure what to do contact a competent professional to assist you The NFPA 70 250 34 35 a...

Page 11: ...of normal fusing 3 Many homes and construction sites are wired for at least 60 to 100 Amp entrance service much greater than the capacity of this portable generator When installing the generator at th...

Page 12: ...load This will ensure the generator is balanced Balanced Unbalanced YOURGEN The WINCO YourGen meter allows you to see useful information about your generator from the front panel by displaying RPMs Vo...

Page 13: ...ge will flash Once the oil has been changed press and hold the cycle button for approximately 5 seconds until the warning has been removed from the display to reset the warning The meter will then rem...

Page 14: ...oroughly air dry DO NOT oil the pre cleaner 7 Install the pre cleaner F to the air filter E 8 Assemble the dry pre cleaner F to the air filter E 9 Install the air filter and secure with the retainer D...

Page 15: ...installing Spark plug gap is 0 030 Poor spark will also occur if spark plug wire does not fit firmly on spark plug If this happens reform the terminal to fit firmly on spark plug tip CARBON CANISTER D...

Page 16: ...Regulator The following is a list of connections on the AVR These have been factory set and other than voltage adjustment should never be changed VOLT Voltage Rotate clockwise to increase voltage STA...

Page 17: ...ubrication B Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the...

Page 18: ...stator Defective rotor field Defective AVR Circuit breaker trips Defective load Defective receptacle Excessive load Voltage too high Engine speed is too high Generator overheating Overloaded Insuffic...

Page 19: ...19 OPM 110 D G1 G1 G2 G2 G2 N N N N N N N GND GND GND GND GND GND G2 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 G1 G1 G1 RECEPTACLE WIRING DIAGRAM...

Page 20: ...a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use and service will be repaired o...