background image

20

OPM-110/D

www.wincogen.com

CALIFORNIA EVAPORATIVE EMISSION CONTROL

WARRANTY STATEMENT

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board is pleased to explain the evaporative emission control system’s warranty on your model 

2020 generator. In California, new equipment that uses small off-road engines must be designed, built, and equipped 

to meet the State’s stringent anti-smog standards. WINCO must warrant the evaporative emission control system on 

your generator for the period listed below provided there has been no abuse, neglect or improper maintenance of your 

equipment leading to the failure of the evaporative emission control system.

Your evaporative emission control system may include parts such as: carburetor, fuel tank, fuel cap, fuel lines (for liquid fuel 

and fuel vapors), fuel line fittings, fuel line clamps, carbon canisters, and carbon canister mounting brackets.

MANUFACTURER’S WARRANTY COVERAGE

The evaporative emission control system is warranted for two years. If any evaporative emission related parts on your 

equipment are defective, the parts will be repaired or replaced by WINCO.

WINCO warrants to the original purchaser for 36 months or up to 1000 hours that goods manufactured or supplied by 

it will be free from defects in workmanship and material, provided such goods are installed, operated and maintained in 

accordance with WINCO written instructions and applicable codes. 

WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the 

product. At WINCO’s option, material found to be defective in material or workmanship under normal use and service 

will be repaired or replaced. For warranty service, return the product within the warranty period, to your nearest WINCO 

Authorized Service Center or to WINCO in Le Center Minnesota. 

Duration Consumer, Commercial and Rental

Parts & Labor: 24 Months

Parts Only: 24-36 Months

EXCLUSIONS:

•   Normal maintenance consumables or labor.

•  This warranty does not cover travel time, mileage or labor for removal or re-installation of WINCO product from its 

 application. 

•  Normal wear and tear.

•  Costs of rental equipment. 

•  WINCO does not warrant engines. Engines are covered exclusively by the warranties of their respective manufacturers. 

•  WINCO does not warrant component parts that are warranted by their respective manufacturers. 

•  WINCO does not warrant modifications or alterations which were not made by WINCO. 

•  WINCO does not warrant products which have been subjected to misuse and/or negligence or have been involved in 

 

an accident. Proof of proper maintenance must be furnished upon request. 

THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE NO OTHER 

WARRANTIES, EXPRESSED OR IMPLIED, OR OTHERWISE CREATED, INCLUDING BUT NOT LIMITED TO WARRANTIES OF 

MERCHANTABILITY, OR WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.

WINCO is liable for the repair or replacement of the product only and is not liable for incidental or consequential damages 

as permitted by your state. This warranty gives you specific legal rights which may vary from state to state. 

ENGINE GENERATOR SET 

36 MONTH 

LIMITED WARRANTY

Summary of Contents for WL22000VA

Page 1: ...tact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DA...

Page 2: ...TOR MAINTENANCE CLEANING TROUBLESHOOTING 18 RECEPTACLE WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should...

Page 3: ...20 C Stator Resistance 0 366 Ohms 20 C Exciter Rotor Resistance 1 453 Ohms 20 C Exciter Stator Resistance 15 71 Ohms 20 C AVR DSR ENGINE Engine Manufacturer Briggs Stratton Engine Model Number 613477...

Page 4: ...with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back into closed room...

Page 5: ...e performance these units should never be run in small compartments without positive fresh air flow RESTRICTED USES DO NOT remove from the cradle assembly Removal of the generator from the cradle asse...

Page 6: ...about the same amount of current to run them whether they are Repulsion Induction RI Capacitor Cap or Split Phase SP type If the electric motor is connected to a hard starting load such as an air comp...

Page 7: ...ator must be on a level surface before you check or add oil to the system The necessity of using the correct oil and keeping the crankcase full cannot be overemphasized Engine failures resulting from...

Page 8: ...safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the Bat terminal Make sure all connections are clean an tight Reverse the sequenc...

Page 9: ...asoline is blended to improve starting Do not use summer grade gasoline 2 HOT WEATHER A Use the proper oil for the temperature expected B Use only summer blended gasoline Using gasoline left over from...

Page 10: ...nt Carefully evaluate your planned use of your generator to understand which grounding you require If you are not sure what to do contact a competent professional to assist you The NFPA 70 250 34 35 a...

Page 11: ...of normal fusing 3 Many homes and construction sites are wired for at least 60 to 100 Amp entrance service much greater than the capacity of this portable generator When installing the generator at th...

Page 12: ...load This will ensure the generator is balanced Balanced Unbalanced YOURGEN The WINCO YourGen meter allows you to see useful information about your generator from the front panel by displaying RPMs Vo...

Page 13: ...ge will flash Once the oil has been changed press and hold the cycle button for approximately 5 seconds until the warning has been removed from the display to reset the warning The meter will then rem...

Page 14: ...oroughly air dry DO NOT oil the pre cleaner 7 Install the pre cleaner F to the air filter E 8 Assemble the dry pre cleaner F to the air filter E 9 Install the air filter and secure with the retainer D...

Page 15: ...installing Spark plug gap is 0 030 Poor spark will also occur if spark plug wire does not fit firmly on spark plug If this happens reform the terminal to fit firmly on spark plug tip CARBON CANISTER D...

Page 16: ...Regulator The following is a list of connections on the AVR These have been factory set and other than voltage adjustment should never be changed VOLT Voltage Rotate clockwise to increase voltage STA...

Page 17: ...ubrication B Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the...

Page 18: ...stator Defective rotor field Defective AVR Circuit breaker trips Defective load Defective receptacle Excessive load Voltage too high Engine speed is too high Generator overheating Overloaded Insuffic...

Page 19: ...19 OPM 110 D G1 G1 G2 G2 G2 N N N N N N N GND GND GND GND GND GND G2 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 G1 G1 G1 RECEPTACLE WIRING DIAGRAM...

Page 20: ...a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use and service will be repaired o...

Reviews: