INITIAL START UP

The throttle control on these generators is preset and 

locked to operate at 3600 RPM (nominal) with no load 

speed set at 3690 RPM. Only a trained service technician 

should be allowed to adjust this speed setting.

NOTICE: ENGINE START LOCKOUT

This unit will not start if it is low on oil. The lubricating oil 

level must be at the full mark before the engine will start 

and run.

BASIC OPERATION

CAUTION: EQUIPMENT DAMAGE:

Always start the unit with the circuit breaker open, never 

start with the load applied. Always keep the battery 

charged, especially during cold weather operation.

  1. Check oil level, refill as needed.

  2. Turn on the fuel supply.

  3. Move the choke to the full “ON” position for starting. A 

    warm engine will require less choking than a cold one.

  4. Turn the key to the start position. The starter life is 

    improved by using shorter start cycles. Do not operate 

    the starter more than 15 seconds during each minute. 

    Repeat as necessary.

  5. When the engine starts, release the key and open the 

  choke 

gradually.

  6. The engine should promptly come up to operating 

  speed.

CAUTION: EQUIPMENT DAMAGE

Never permit the choke to remain on after the engine has 

run for a short time. It is not necessary to choke the engine 

when it is warm. Avoid over-choking.

STARTING HINTS

1. COLD WEATHER

  A. Use the proper oil for the temperature expected.

  B. Use fresh winter grade fuel. Winter grade gasoline is 

    blended to improve starting. Do not use summer grade 

  gasoline.

2. HOT WEATHER

  A. Use the proper oil for the temperature expected.

  B. Use only summer blended gasoline. Using gasoline left 

    over from winter may cause the unit to vapor lock.

STOPPING AND STORING

  1. Move the key to the “OFF” position.

  2. Turn off the fuel supply valve.

  3. Before extended storage (over 30 days) certain 

    precautions must be taken to ensure the fuel doesn’t 

    deteriorate and clog the fuel system.

NOTE:

 The use of a fuel additive, such as Sta-Bil or 

equivalent will minimize the formation of gum deposits 

during storage. The additive may be added to gasoline in 

the engines fuel tank or to gasoline in a storage container.

  A. Add the fuel stabilizer to the fuel in the tank and run 

    for 2 minutes to circulate the stabilizer throughout the 

  fuel 

system.

  B. Remove the remaining fuel from the fuel tank, it must 

    be drained into an approved container.

  C. Start the engine and allow it to run until all the fuel in 

    the carburetor and the fuel lines has been used up and 

    the engine stops.

NOTE:

 Running the engine to use up the fuel in the lines 

and carburetor will still leave a small amount of fuel in 

carburetor. It is best extended storage practice to treat the 

fuel before draining.

  D. While the engine is warm, drain the oil and refill with 

  fresh 

oil.

  E. Remove the spark plug, pour approximately 1/2 oz. 

    (15cc) of engine oil into the cylinder and crank slowly 

    to distribute the oil. Replace the spark plug.

  E. Clean dirt and chaff from cylinder, cylinder head fins, 

    blower housing, screen, and muffler areas.

  F. Store in a clean and dry area.

Summary of Contents for WL22000VA

Page 1: ...tact us concerning this unit it will help us to respond to your needs faster MODEL _________________________________________________ SERIAL NUMBER _________________________________________ PURCHASE DA...

Page 2: ...TOR MAINTENANCE CLEANING TROUBLESHOOTING 18 RECEPTACLE WIRING DIAGRAM 19 CA EVAP EMISSION CONTROL 20 LIMITED WARRANTY 20 SAVE THESE INSTRUCTIONS This manual contains important instructions that should...

Page 3: ...20 C Stator Resistance 0 366 Ohms 20 C Exciter Rotor Resistance 1 453 Ohms 20 C Exciter Stator Resistance 15 71 Ohms 20 C AVR DSR ENGINE Engine Manufacturer Briggs Stratton Engine Model Number 613477...

Page 4: ...with fresh air A Operate only in well ventilated areas B Never operate indoors including attached garages C Never operate the unit in such a way as to allow exhaust gases to seep back into closed room...

Page 5: ...e performance these units should never be run in small compartments without positive fresh air flow RESTRICTED USES DO NOT remove from the cradle assembly Removal of the generator from the cradle asse...

Page 6: ...about the same amount of current to run them whether they are Repulsion Induction RI Capacitor Cap or Split Phase SP type If the electric motor is connected to a hard starting load such as an air comp...

Page 7: ...ator must be on a level surface before you check or add oil to the system The necessity of using the correct oil and keeping the crankcase full cannot be overemphasized Engine failures resulting from...

Page 8: ...safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the Bat terminal Make sure all connections are clean an tight Reverse the sequenc...

Page 9: ...asoline is blended to improve starting Do not use summer grade gasoline 2 HOT WEATHER A Use the proper oil for the temperature expected B Use only summer blended gasoline Using gasoline left over from...

Page 10: ...nt Carefully evaluate your planned use of your generator to understand which grounding you require If you are not sure what to do contact a competent professional to assist you The NFPA 70 250 34 35 a...

Page 11: ...of normal fusing 3 Many homes and construction sites are wired for at least 60 to 100 Amp entrance service much greater than the capacity of this portable generator When installing the generator at th...

Page 12: ...load This will ensure the generator is balanced Balanced Unbalanced YOURGEN The WINCO YourGen meter allows you to see useful information about your generator from the front panel by displaying RPMs Vo...

Page 13: ...ge will flash Once the oil has been changed press and hold the cycle button for approximately 5 seconds until the warning has been removed from the display to reset the warning The meter will then rem...

Page 14: ...oroughly air dry DO NOT oil the pre cleaner 7 Install the pre cleaner F to the air filter E 8 Assemble the dry pre cleaner F to the air filter E 9 Install the air filter and secure with the retainer D...

Page 15: ...installing Spark plug gap is 0 030 Poor spark will also occur if spark plug wire does not fit firmly on spark plug If this happens reform the terminal to fit firmly on spark plug tip CARBON CANISTER D...

Page 16: ...Regulator The following is a list of connections on the AVR These have been factory set and other than voltage adjustment should never be changed VOLT Voltage Rotate clockwise to increase voltage STA...

Page 17: ...ubrication B Receptacles Quality receptacles have been utilized If a receptacle should become cracked or otherwise damaged replace it Using damaged or cracked receptacles can be both dangerous to the...

Page 18: ...stator Defective rotor field Defective AVR Circuit breaker trips Defective load Defective receptacle Excessive load Voltage too high Engine speed is too high Generator overheating Overloaded Insuffic...

Page 19: ...19 OPM 110 D G1 G1 G2 G2 G2 N N N N N N N GND GND GND GND GND GND G2 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 G1 G1 G1 RECEPTACLE WIRING DIAGRAM...

Page 20: ...a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use and service will be repaired o...

Reviews: