CALIFORNIA EVAPORATIVE EMISSION CONTROL

WARRANTY STATEMENT

YOUR WARRANTY RIGHTS AND OBLIGATIONS

The California Air Resources Board is pleased to explain the evaporative emission control system’s warranty on your model 

2020 generator. In California, new equipment that uses small off-road engines must be designed, built, and equipped 

to meet the State’s stringent anti-smog standards. WINCO must warrant the evaporative emission control system on 

your generator for the period listed below provided there has been no abuse, neglect or improper maintenance of your 

equipment leading to the failure of the evaporative emission control system.

Your evaporative emission control system may include parts such as: carburetor, fuel tank, fuel cap, fuel lines (for liquid fuel 

and fuel vapors), fuel line fittings, fuel line clamps, carbon canisters, and carbon canister mounting brackets.

MANUFACTURER’S WARRANTY COVERAGE

The evaporative emission control system is warranted for two years. If any evaporative emission related parts on your 

equipment are defective, the parts will be repaired or replaced by WINCO.

WINCO warrants to the original purchaser for 36 months or 1000 hours, whichever occurs first, that goods manufactured 

or supplied by it will be free from defects in workmanship and material, provided such goods are installed, operated and 

maintained in accordance with WINCO written instructions and applicable codes. 

WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the 

product. At WINCO’s option, material found to be defective in material or workmanship under normal use and service 

will be repaired or replaced. For warranty service, return the product within the warranty period, to your nearest WINCO 

Authorized Service Center or to WINCO in Le Center Minnesota. 

Duration Consumer, Commercial and Rental

Parts & Labor: 24 Months

Parts Only: 24-36 Months

EXCLUSIONS:

•   Normal maintenance consumables or labor.

•  This warranty does not cover travel time, mileage or labor for removal or re-installation of WINCO product from its 

 application. 

•  Normal wear and tear.

•  Costs of rental equipment. 

•  WINCO does not warrant engines. Engines are covered exclusively by the warranties of their respective manufacturers. 

•  WINCO does not warrant component parts that are warranted by their respective manufacturers. 

•  WINCO does not warrant modifications or alterations which were not made by WINCO. 

•  WINCO does not warrant products which have been subjected to misuse and/or negligence or have been involved in 

 

an accident. Proof of proper maintenance must be furnished upon request. 

THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE DESCRIBED HEREIN. THERE ARE NO OTHER 

WARRANTIES, EXPRESSED OR IMPLIED, OR OTHERWISE CREATED, INCLUDING BUT NOT LIMITED TO WARRANTIES OF 

MERCHANTABILITY, OR WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.

WINCO is liable for the repair or replacement of the product only and is not liable for incidental or consequential damages 

as permitted by your state. This warranty gives you specific legal rights which may vary from state to state. 

ENGINE GENERATOR SET 

36 MONTH 

LIMITED WARRANTY

Summary of Contents for WL12000HE-04/A

Page 1: ...ever need to contact us concerning this unit it will help us to respond to your needs faster MODEL __________________________________________________ SERIAL NUMBER ___________________________________...

Page 2: ...AVR WIRING 13 GENERATOR CARE 14 EXERCISING THE GENERATOR GENERATOR MAINTENANCE CLEANING TROUBLESHOOTING TABLE 14 WIRING DIAGRAM 15 CALIFORNIA EVAPORATIVE EMISSION CONTROL 16 LIMITED WARRANTY 16 SAVE T...

Page 3: ...IRE HAZARD Gasoline and other fuels present a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke...

Page 4: ...w enough free flow of fresh air to reach the engine generator set for cooling and will cause the unit to overheat damaging both the engine and generator Small compartments will also develop hot spots...

Page 5: ...se motors are very hard to start and require 5 to 7 times as much starting current as running current Capacitor motors are easier to start and usually require 2 to 4 times as much starting current as...

Page 6: ...ill with the recommended oil to the upper limit mark on the oil level dipstick Running the engine with a low oil level can cause engine damage This type of damage is not covered by the Distributor s L...

Page 7: ...EGATIVE battery terminal to GROUND For your safety always connect the positive battery cable to the bat terminal first Then connect the negative battery cable to the Bat terminal Make sure all connect...

Page 8: ...Turn the engine switch to the START position and hold it there until the engine starts If the engine fails to start within 5 seconds release the engine switch and wait at least 10 seconds before oper...

Page 9: ...ngine generator described in this manual are approximately as follows under varying loads LOAD vs OUTPUT Generator Load Speed RPM Frequency Hz Voltage None 3690 61 5 125V Half 3600 60 0 120V Full 3510...

Page 10: ...d which grounding you require If you are not sure what to do contact a competent professional to assist you The NFPA 70 250 34 35 are good technical references STANDARD PORTABLE GENERATOR Your WINCO p...

Page 11: ...ution panel must be installed by a licensed electrician according to all applicable codes The electrician will move the critical circuits to be powered during the outage to the emergency panel Keep in...

Page 12: ...d by this engine for refuelling With the engine stopped and on a level surface remove the fuel filler cap and check the fuel level Refill the tank if the fuel level is low Never use stale or contamina...

Page 13: ...ug that came in the engine and check gap before installing Spark plug gap is 0 030 Poor spark will also occur if spark plug wire does not fit firmly on spark plug If this happens reform the terminal t...

Page 14: ...The high pressure spray could contaminate the fuel system and the generator components 1 Keep the air inlet screen on both the engine and generator free of any dirt or debris to ensure proper cooling...

Page 15: ...15 OPM 152 A WIRING DIAGRAM GND GND GND GND N N N N G3 G3 G3 G3 G2 G2 G2 G2 G1 G1 G1 G1 GND GND N G3 G3 G2 G2 G1 G1 208V 230V 480V...

Page 16: ...nd Purchaser s sole remedy for a failure under this warranty shall be limited to the repair of the product At WINCO s option material found to be defective in material or workmanship under normal use...

Reviews: