Winco W100PTO Owner'S Manual Download Page 2

Read and understand all instructions in this
manual before starting and operating the
generator set.

USING THIS MANUAL

Congratulations on your choice of a Winco generator set.

You have selected a high-quality, precision-engineered
generator set designed and tested to give you years of
satisfactory standby service.

To get the best performance from your new generator

set, it is important that you carefully read and follow the
operating instructions in this manual.

Should you experience a problem please follow the

“Things To Check” near the end of this manual. The warranty
listed in this manual describes what you can expect from
WINCO should you need service assistance in the future.

TABLE OF CONTENTS

INTRODUCTION

i

GUIDE TO PRODUCT SAFETY

1

DESCRIPTION

2

PREPARING THE UNIT

2

Unpacking the unit

2

Specifications

2

Assembly

2

INSTALLATION

Foundation Mounting

3

Trailer Mounting

3

ELECTRICAL CONNECTIONS

4

OPERATION

5

Pre-Start Checks

5

Starting    Procedure

6

Stopping

6

 MAINTENANCE

7

Lubrication

7

Cleaning

8

Storage

8

Trouble Shooting Table

8

GENERATOR CONNECTIONS

120/240 Volt Single Phase

10

120/240 Volt Three Phase

10

120/208 Volt Three Phase

11

277/480 Volt Three Phase

11

GENERATOR RECEPTACLE PANELS

12

Convenience Receptacle Wiring

13

36 MONTH WARRANTY

14

PROPER USE AND INSTALLATION

You must be sure your new generator set is:
*

Properly serviced before operating

*

Operated in a well ventilated area

*

Exhaust gases are dispersed safely

*

Wired by a qualified electrician

*

Operated only for its designed purposes

*

Used only by operators who understand its operation

*

Properly maintained

COPY YOUR MODEL AND SERIAL NUMBER HERE

No other WINCO generator has the same serial number as
yours.  It is important that you record the number and other
vital information here, if you should ever need to contact us on
this unit it will help us to respond to your needs faster.

MODEL____________________________________

SERIAL NUMBER____________________________

PURCHASE DATE____________________________

DEALER___________________________________

Summary of Contents for W100PTO

Page 1: ...EV 3 W85PTOS W100PTO W105PTOT W135PTOS W145PTOT W150PTOS W165PTOT Tractor Drive PTO Generators OWNERS MANUAL INSTALLATION AND OPERATION INSTRUCTIONS SAFETY FIRST READ THIS MANUAL BEFORE OPERATING YOUR...

Page 2: ...ION 5 Pre Start Checks 5 Starting Procedure 6 Stopping 6 MAINTENANCE 7 Lubrication 7 Cleaning 8 Storage 8 TroubleShootingTable 8 GENERATORCONNECTIONS 120 240 Volt Single Phase 10 120 240 Volt Three Ph...

Page 3: ...ion and or fire a Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropriate 3 DEADLY EXHAUST GAS Exhaust fumes from any engine contain carbon monoxid...

Page 4: ...carton with the large carton 4 Open the subpack carton and make sure it contains a Generator instruction manual b Load disconnect plug disassembled in bag 5 Remove the four bolts which hold down the...

Page 5: ...less than 15 degrees during generator operation even though the mechanical design of the tumbling bar would allow greater misalignment The following wire sizes are recommended for each unit Generator...

Page 6: ...ans should install electrical wiring Wiring must conform to all applicable national state and local codes Reference National Fire Protection Association Manual No 70 National Electrical Code DANGER PE...

Page 7: ...t its starting current which is a lot higher Motor starting current requirements vary greatly by motor size and type Repulsion induction type motors are the easiest to start typically using 1 1 2 to 2...

Page 8: ...OTE EquipmentDamage If the load includes motors turn them on one at a time highest starting current motor first next highest second etc Adjust engine throttle to keep generator output under load at 60...

Page 9: ...the generator The drive shaft tumbling bar requires greasing Keep the universal joints in the coupling shaft free from grease and dirt buildup NOTE Do not over lubricate the universal joints See Figur...

Page 10: ...erloaded 2 Reduce load if it is higher than the rated capacity of the generator See generator nameplate 3 Inadequate engine horsepower 3 Generator requires 2 HP 1000 watts output Obtain larger engine...

Page 11: ...wer take off misalignment 1 Correct misalignment It should be less than 15 degrees vibration excessive 2 Loose mounting nuts and bolts 2 Tighten mounting nuts and bolts repair hold down stud or hold d...

Page 12: ...Page 10 60706 160REV3 3117 30 GENERATOR CONNECTIONS 120 240 VOLT SINGLEPHASE GENERATOR CONNECTIONS 120 240 VOLT THREEPHASE...

Page 13: ...Page 11 60706 160REV3 3117 30 GENERATOR CONNECTIONS 120 208 VOLT THREEPHASE GENERATOR CONNECTIONS 277 480 VOLT THREEPHASE...

Page 14: ...Page 12 60706 160REV3 3117 30 GENERATOR RECEPTACLE PANEL W105PTOT 4 W105PTOT 17 GENERATOR RECEPTACLE PANEL W85PTOS 3 W100PTOS 3 GENERATOR RECEPTACLE PANEL W105PTOT 18...

Page 15: ...EV3 3117 30 GENERATOR RECEPTACLE PANEL ON MODELS W135PTOS 3 W145PTOT 4 W145PTOT 17 W150PTOS 3 GENERATOR RECEPTACLE PANEL ON MODEL W165PTOT 18 GENERATOR CONVENIENCE RECEPTACLE WIRING ON ALL MODELS EXCE...

Page 16: ...limitationsonthedurationofanimpliedwarranty andsomestatesdonotallow the exclusion or limitation of incidental or consequential damages so that above limitation or exclusion may notapplytoyou Thiswarra...

Reviews: