background image

16

REV D

60706-231

GENERATORS

WINCO INC. • 225 S. CORDOVA AVE. • LE CENTER, MN  56057 • 507-357-6821

24 MONTH LIMITED WARRANTY

WINCO,  Incorporated warrants to the original purchaser for 24 months, that goods manufactured or supplied by it 

will be free from defects in workmanship and material, provided such goods are installed, operated and maintained in 

accordance with WINCO written instructions.  

WINCO’s sole liability, and Purchaser’s sole remedy for a failure under this warranty, shall be limited to the repair of the 

product.  At WINCO’s option, material found to be defective in material or workmanship under normal use and service 

will be repaired or replaced.  For warranty service, return the product within 24 months from the date of purchase, 

transportation charges prepaid, to your nearest WINCO Authorized Service Center or to WINCO, Inc. at Le Center 

Minnesota.  

THERE IS NO OTHER EXPRESS WARRANTY.

To the extent permitted by law, any and all warranties, including those of merchantability and fitness for a particular 

purpose, are limited to 24 months from date of purchase.  In no event is WINCO liable for incidental or consequential 

damages.  

Note: Some states do not allow limitation on the duration of implied warranty and some states do not allow the exclusion 

or limitation of incidental or consequential damages, so the above limitations may not apply in every instance.  This 

warranty gives you specific legal rights which may vary from state to state.

WINCO reserves the right to change or improve its products without incurring any obligations to make such changes or 

improvement on products purchased previously.

EXCLUSIONS:

WINCO does not warrant Engines. Engines are covered exclusively by the warranties of their respective manufacturers, 

see enclosed warranties.

WINCO does not warrant Component Parts that are warranted by their respective manufacturers.

WINCO does not warrant modifications or alterations which were not made by WINCO, Inc.

WINCO does not warrant products which have been subjected to misuse and/or negligence or have been involved in an 

accident.

This warranty does not include travel time, mileage, or labor for removal or re-installation of WINCO product from its 

application.

Summary of Contents for EC18000VE/D

Page 1: ...WINCO INC 225 S CORDOVA AVE LE CENTER MN 56057 507 357 6821 SERVICE DEPT 507 357 6831 www wincogen com INSTALLATION AND OPERATORS EC18000VE D EC22000VE A GENERATORS MANUAL...

Page 2: ...ou have selected a high quality precision engineered generator designed and tested to give you years of satisfactory service To get the best performance from your new generator it is important that yo...

Page 3: ...4 0 006 in Exhaust Valve Clearance 0 007 0 009 in Oil Capacity 78 80 oz 2 4 2 5 qts EC22000VE Starting Watts 22 000 22 000 22 000 22 000 Running Watts 19 000 19 000 19 000 19 000 Volts 120 240 120 208...

Page 4: ...resent a hazard of possible explosion and or fire A Do not refuel when the engine is running or hot B Keep fuel containers out of reach of children C Do not smoke or use open flame near the generator...

Page 5: ...pliance or tool nameplates for the current and voltage to ensure compatibility Remember tha power utilized from C reduces the power available from both A and B and vice versa The EC22000 utilizes the...

Page 6: ...nt line This is to prevent the escape of fuel vapors in to the atmosphere 3 You need to have a primer bulb in the fuel line to prime the fuel from the tank to the fuel pump The vacuum fuel pump on the...

Page 7: ...th are going to vary depending on your installation These engines are all negative ground The positive battery cable must be connected to the open large terminal on the start solenoid This terminal ma...

Page 8: ...slightly lower voltage when the generator is loaded to its full capacity than when running no load The slight variation in speed also affects the frequency of the output current This frequency variati...

Page 9: ...ers mounted in some type of distribution panel This location will also be where you will install your neutral to ground bond You must wire four separate wires from the generator 2 hot 1 neutral and 1...

Page 10: ...e and remove the spark plug wire to prevent it from accidently being started b Remove oil drain plug at base of the engine Ref B and drain the oil into an approved container c Remove the oil lter Ref...

Page 11: ...p the air inlet screen on both the engine and generator free of any dirt or debris to ensure proper cooling At least yearly remove the blower housing on the engine and clean the chaff and dirt out of...

Page 12: ...6 FLAT WASHER 2 9 467 000 HHCS 5 16 18X 75 2 REVISIONS REV IRN DESCRIPTION DATE BY APP D A ORIGINAL MVW B REDESIGNED RECEPTACLE BOX 6 20 12 PJY MVW C 3630 60706 231 ADDED 3 24 2015 KS DRC D 5271 REPLA...

Page 13: ...13 REV D 60706 231 EC18000VE EC22000VE DISTRIBUTION WIRING SCHEMATICS 120 240 SINGLE PHASE 120 208 120 240 THREE PHASE 277 480 THREE PHASE...

Page 14: ...OW WYE THREE PHASE LO 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS Page 14 0210 10 REV B 60706 197 EE PHASE AC WIRING H AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS E HIGH WYE S EC22000VE AC WIRI...

Page 15: ...REV B THREE PHASE AC WIRING D SINGLE PHASE AC WIRING SINGLE PHASE 120 240 VOLTS THREE PHASE D 120 240 VOLTS E PHASE AC WIRING DELTA E PHASE AC WIRING GLE PHASE 240 VOLTS THREE PHASE DELTA 120 240 VOLT...

Page 16: ...a particular purpose are limited to 24 months from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of imp...

Reviews: